Bosch DHD905AUC Specifications Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4
EnglishFrançaisEspañol
INSTALL COOKTOP
1. Align the cooktop with the downdraft and fasten cooktop in
place.
Note: Accurate alignment of cooktop and downdraft is necessary
to ensure that there is no interference when air vent is raised and
lowered. There should be a gap of 1/32"-1/16" between the back
of the cooktop and the front of the downdraft cover.3. Remove
switch cover from right end of air vent.
USE AND CARE
Always turn the downdraft blower on before you begin cooking to
establish an air flow in the kitchen. Let the blower run for a few
minutes to clean the air after you turn the cooktop off. This will
keep the whole kitchen cleaner and brighter.the activating switch
is pressed and the air vent rises.
OPERATION
UP / DOWN --- Raises and lowers vent.
Turns blower ON when vent is UP and OFF when
vent is DOWN.
DELAY --------- Allows blower to run for 5 min. after button is
pressed. Blower will run for 5 min. - then shut
OFF. VENT WILL NOT LOWER. You must press
UP / DOWN to lower vent.
LOW / MED / HIGH ----- Operates blower at 3 different speed
levels. Press button ONCE to turn blower
ON to desired speed. Press button
AGAIN to turn blower OFF.
FILTER LIGHT ----------- Comes ON after 30 hours of operation
to remind you to clean filters. Press
button to reset.
OPTIONAL DOOR KITS
MODEL NO. DESCRIPTION
DHZ8020 30" White
DHZ8060 30" Black
DHZ9020 36" White
DHZ9060 36"Black
CLEANING
SERVICING
WARNING: Always disconnect electric
power supply before cleaning unit.
Use a mild detergent suitable for painted surfaces. DO NOT USE
ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING
POWDERS. Vacuum blower to clean. Do not immerse blower in
water.
Wash the 2 aluminum/stainless steel grease filters in a mild
detergent solution or a dishwasher. Remove them from the air
vent by grasping the tab at the top of each filter.
WARNING: Always disconnect electric
power supply before servicing unit.
It may be necessary to remove the downdraft blower system from
the cabinet in order to service components such as the blower
motor or air vent mechanism.
Disconnect power to the cooktop and remove it first. Reverse the
steps under “MOUNT THE UNIT” to remove the downdraft from
the cabinet.