Bosch 430 Operations Instructions Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
Video Recorder 430/451 Series Configuration menu | en 61
Bosch Security Systems Installation and Operation manual F.01U.168.054 | v2.0 | 2012.05
6.5 Network
6.5.1 TCP/IP
Figure 6.16 Network - TCP/IP
1. Enable DHCP to have the IP address, subnet mask, and default gateway assigned
automatically by the network server.
If DHCP is disabled, fill in the IP address, the Subnet mask, the default Gateway,
and the Primary DNS server address. If required, change the default HTTP port no.
(80) to a new value.
2. Restrict the network Bandwidth limit by entering a value between 256 Kbps and
100 Mbps. If 256 or 512_Kbps is selected, the DVR automatically selects I-frame only
video at 1 IPS for transmission over the low bandwidth network connection.
(A video clip is not attached to an e-mail if 256 or 512_Kbps is selected.)
3. Enable the RTSP server to stream live video (for example, to a smart phone). If RTSP is
enabled (on), enter a TCP/IP port number (default port 554).
4. ICMP is set to Off by default (ping is not available). Set ICMP to On if you are using
Control Center software version 3.34 or lower).
6.5.2 Streaming to mobile devices
The Real Time Streaming Protocol (RTSP) feature allows live video streaming over the
network.
Attention:
If you enable this feature (RTSP server to On) and the firewall on a ADSL router is opened,
anybody can view the cameras. There is no log-on user ID or password to protect a camera
live image.
6.5.3 Connecting using a smart mobile phone
Your smart phone should support RTSP network protocol and includes a RTSP capable player
application that can display H.264 video streams. The RTSP transports the remote (network)
Page view 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 91 92

Comments to this Manuals

No comments