Bosch DiBos Micro Installation Guide Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 158
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
24 en | Device Connections DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
3.1.4 I/O Card for DiBos
The following can be set for the I/O card:
the relay outputs (NO = normally open, NC = normally closed)
the malfunction outputs (NO = normally open, NC = normally closed)
1 Relay outputs:
The setting is printed on the PCB.
Relay outputs 1–8: open (NO = normally open)
Relay outputs 9–16: closed (NC = normally closed)
2 Malfunction output:
The setting is printed on the PCB.
Bridge position up:
Open (MAL NO = malfunction normally open)
Bridge position down:
Closed (MAL NC = malfunction normally closed)
NOTICE!
The I/O card must be removed to change the bridge settings.