98 en | Default Configuration DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
2 Trigger In the list field, select the inputs or cameras with motion
detection whose triggering starts the job.
The following are displayed as triggers:
All types of inputs
Cameras with activated motion detection or activated
tamper detection
JPEG IP cameras and MPEG4 IP cameras with motion
detection
Skimming protection of foyer card reader
Note:
The triggers for cameras with motion detection are only
displayed after the camera has been configured (see
Section 6.2.3 Specifying Monitoring Zone for Motion
Cameras,Section 6.2.8 Configuring JPEG IP Cameras and
Section 6.2.9 Configuring MPEG4 IP Cameras
And All selected inputs and cameras with motion detection must
trigger in order to start the job.
Or Only one input or one camera with motion detection must
trigger in order to start the job.
3 Day I Night I Weekend
...
Select the time profile. The job is assigned to this time
profile.
Note:
Only the time profiles configured under Time periods are
displayed.
4 Authorization level Select the authorization level.
Note:
The name of the authorization level and its connection
password must match in the local station and in the remote
station to which the alarm is transmitted. However, the
individual enabling of authorization levels, for example
enabled cameras, relays etc., may be different. Enabling of
the authorization level in the remote station takes place when
dialing into that remote station.
Authorization for alarm transmission must be activated in the
Authorization levels menu.
5 Cameras Select the cameras whose images you want to transmit to the
remote station.
6 Remote stations The list field contains all remote stations known in the
system.
Select the remote station and, if necessary, one or more
replacement remote stations to which the alarm is to be
transmitted and click . The remote station is added to the
Alarm recipient list field.