3. Guidelines for installation and electrical connections
3.7. Additional capacitance on the DC bus
It is possible to connect additional capacitors (CZ 1.02) or additional capacitance
modules (TCM) to the DC bus to increase the capacity of the KDV 2.3.
An additional capacitance of 4 mF is needed to utilize this.
In a few applications, it might be necessary for the drives to back up in the event
of a power failure. The energy stored in the DC bus can be used for this action.
The DC bus capacity can be increased with the use of additional capacitors.
A maximum of 8 mF additional capacitors may be connected. Each mF of
additional capacitance can store up to 30 Ws.
3.8. Smoothing choke
The KDV 2.3 must be operated with a smoothing choke in the "L+ line" from
a DC bus load of 9Kw:
DC bus load
up to 9 kW
up to 15 kW
greater than 15 kW
Smoothing choke required
(see Section 7.6 for technical data)
none
GLD 13
GLD 12
Figure 3.8: Required smoothing choke
3.9. Electronics and internal blower power supply
Supply terminal: X10a/1 - X10a/3
Terminal diameter: maximum 1.5 mm
2
Terminal voltage: AC 230 V; 50 to 60 Hz
Terminal capacity: 500 VA (if electronics supply reaches maximum
load)
Recommended fusing: Circuit breaker 10 A (tripping characteristic C:
magnetic release between 7 to ten times rated
current)
Electronics supply
External blower supply
Supply terminal: X13
Terminal diameter: maximum 1.5 mm
2
Terminal voltage: LE3-220 blower: AC 220/230 V; 50 to 60 Hz
LE3-115 blower: AC 110/115 V; 50 to 60 Hz
Terminal capacity: 70 VA for each blower
Increasing power
Energy capacitor for
power failures
Tap electronics power off of outer conductors L1 and L3 of the
power source (see terminal diagram in Section 3.1). NOTE: X10a/
1 and X9/l1 must have the same phase, and X10a/3 and X9/L3 must
also have same phase! The KDV 2.3 could otherwise be damaged!