4. Control circuits
Q10
F1
L1
L2
L3
K3
K1
K1
1
2
L1
L2
L3
L1
L3
L-
L-
L-
L+ L+
L+
Bb Bb
K4
Y1
4
KDV/Bb1
K3
3
PE
+24V
+/- 10%
UD
756
K4
Bb
control
voltage
supply
Leistungsteil
Supply module
KDV 2
additional drive
modules
drive module
S1
E-stop
control unit
S2
end
position
S5
ON
S4
OFF
Q10 = mains disconnect
RF = drive enable signal from controller
S1 = E-Stop
S2 = limit switch
S4 = power OFF
S5 = power ON
UD = message from KDV "power feed OK"
T1 = power transformer
Y1 = Take delay time of electrically released
holding brake of feed axes into account!
Do not apply velocity command until
100 ms after RF-ON!
0V
SKDV23.fh3
UU
U
Control circuit: • without dynamic brake
• NC control unit brakes the drives in an E-Stop
T1
F2
X10/6
X10/7
K4
U
K4
K10
T1
a
b
K1
power section
Bb1 = supply module ready (drive system)
Bb = drive module ready
F1 = power supply fuses
F2 = electronics and blower fuses
K1 = mains contactor
K3 = decouple Bb1
K4 = dynamic brake contactor
K10 = decouple thermal contact of power transformer
NCB = no command-to-zero with a fault if NC bridge closed
X10/11
X10/12
RF
RF
drive
module
NCBNCB
K10
Figure 4.6: Control circuits for a controlled braking with an E-Stop or power failure