5. Interface descriptions
5.3. Electronics supply working
Transistor output NH, terminal X10/8
Maximum load DC 24V/100mA
Output NH
R >= 240
X10/8
X10/4
0V
L
ϑ
5.6
KDV 2.3
external protective circuits
+24V
NH
L
SPKDV23NH
Operating no power to fault in auxiliary auxiliary voltage
status: the electronics voltage, DC bus functional
voltage functional
Output high-resistance low-resistance high-resistance
Figure 5.2: Protective circuit of the NH transistor output
5.4. Feedback power too high
Output BVW, terminal X10/9 - X10/10
Potential-free contact, maximum load DC 24V/1A
BVW contact
Operating no power to feedback power
status: the electronics too high acceptable
Output open open closed
The bleeder warning contact opens if feedback power is greater than 80% of
continuous bleeder power. If the bleeder load should continue to the rise to the
point of thermal overload, then the Bb1 contact will interrupt power flow. The
response of the drive system to this fault depends on the "NC" bridge (see
section 5.6).