• DOK-POWER*-KDV*2.3****-ANW1-EN-E1,44 • 06.97
2. Applications
2.1. Functional power features of the KDV 2.3
Simplified fusing
Only overload protection for the power supply line is needed. Commercial
power protection switches or slow-blow fuses can be used.
Ground fault monitoring of the attached drives
In the event of a fault, power is immediately switched off by opening the Bb1
contact and signalled via the optical display on the LED.
Drive system response to a power failure
Can be programmed by inserting the external NC bridge circuit:
Without the NC bridge circuit, the drives will brake with maximum torque.
With the NC bridge circuit, there is a signal to the NC control unit via a
potential-free contact. It makes it possible for the NC control unit to brake
the drive to a standstill, protecting expensive tools and workpieces
against damage.
Limiting the charging current of the DC bus capacitors
The charging current need not be taken into consideration when selecting
the switching device for the power supply. The lifespan of the switching
devices is increased.
High control voltage loads
Six drive modules can generally be mounted to one supply module.
Ease of servicing
The signal lines are connected via plug-in terminal screws.
Power ratings by means of additional components
Input power can be configured to meet the demands of the relevant
application.