2. Applications
(1) (2) (3) (4) (5) (6) (7) (8) Additional components
P
DC
P
KB-3
P
KB-03
P
BD
P
BM
W
max
P
m
S smoothing choke additional capacitor
kW kW kW kW kW kWs kW kVA
15 30 90 2 40 100 12 16 GLD 13 ---
22 30 90 2 40 100 17,6 23 GLD 12 CZ 1.02
30 30 90 2 40 100 24 32 GLD 12 TCM 1.1-04
(4) P
BD
= continuous bleeder power
(5) P
BM
= peak bleeder power
(6) W
max
= maximum regenerative energy
(7) P
m
= continuous mechanical power
(8) S = connected power
(1) P
DC
= continuous DC bus power
(2) P
KB-3
= DC bus short-time power for 3
seconds (accelerating main drives)
(3) P
KB-03
= DC bus peak power for 0.3
seconds (accelerating servo drives)
Figure 2.2: Typical KDV 2.3 power ratings by combining additional components
2.2. KDV 2.3 power ratings
It is possible to optimize usable KDV 2.3 to meet the requirements of an
application by combining additional components.