Summary of Contents

Page 1 - D9112 Control/Communicator

R A D I O N I C SD9112 Control/CommunicatorOperation and Installation Manual74-06144-000-C 2/96©

Page 2 - FCC Notices

D9112 Operation & Installation ManualPage 1074-06144-000-C 2/96© 1993-1996 RadionicsOther FeaturesThe D9112 has many programmable features. A sho

Page 3 - Part 68 (Continued)

D9112 Operation & Installation ManualPage 11© 1993 Radionics74-06144-000-C 2/96D9112 Control/Communicator AssemblyThe Radionics D9112 Control/Co

Page 4 - Table of Contents

D9112 Operation & Installation ManualPage 1274-06144-000-C 2/96© 1993-1996 RadionicsListings and ApprovalsFireULUnderwriters Laboratories lists t

Page 5 - 74-06144-000-C 2/96

D9112 Operation & Installation ManualPage 13© 1993 Radionics74-06144-000-C 2/96InstallationBefore You BeginThis Installation section contains a

Page 6 - Figures and Tables

D9112 Operation & Installation ManualPage 1474-06144-000-C 2/96© 1993-1996 RadionicsPremises WiringRun the necessary wiring throughout the premis

Page 7 - Introduction

D9112 Operation & Installation ManualPage 15© 1993 Radionics74-06144-000-C 2/96Locking the Reset PinLocking the Reset Pin disables the panel. Se

Page 8 - Keyswitch

D9112 Operation & Installation ManualPage 1674-06144-000-C 2/96© 1993-1996 RadionicsFinishing the InstallationEarth ground and reset pin first: M

Page 9 - Event Log

D9112 Operation & Installation ManualPage 17© 1993 Radionics74-06144-000-C 2/96Make the Telephone ConnectionsSee Telephone Connections. If you a

Page 10 - Other Features

D9112 Operation & Installation ManualPage 1874-06144-000-C 2/96© 1993-1996 RadionicsTesting the SystemAfter finishing the installation and progra

Page 11 - Ordered Separately

D9112 Operation & Installation ManualPage 19© 1993 Radionics74-06144-000-C 2/96Power SupplyPrimary Power Terminals 1 2Primary (AC) Power Circuit

Page 12 - Listings and Approvals

D9112 Operation & Installation ManualPage 274-06144-000-C 2/96© 1993-1996 RadionicsNoticeThe material and instructions covered in this manual hav

Page 13 - Installation

D9112 Operation & Installation ManualPage 2074-06144-000-C 2/96© 1993-1996 RadionicsSecondary Power Terminals 4 5Secondary (DC) PowerA 12V, 7 Ah

Page 14 - Installing the D9112 Assembly

D9112 Operation & Installation ManualPage 21© 1993 Radionics74-06144-000-C 2/96Battery Supervision (Continued)When battery voltage returns to 13

Page 15 - Locking the Reset Pin

D9112 Operation & Installation ManualPage 2274-06144-000-C 2/96© 1993-1996 RadionicsCharging Status and Low Battery LEDsCharging Status LED (Yell

Page 16 - Finishing the Installation

D9112 Operation & Installation ManualPage 23© 1993 Radionics74-06144-000-C 2/96Power OutputsCircuit ProtectionThree self-resetting thermal circu

Page 17 - Install the Point Chart Label

D9112 Operation & Installation ManualPage 2474-06144-000-C 2/96© 1993-1996 RadionicsAvailable Power (Continued)Accessory Connector (J2)The D128

Page 18 - Testing the System

D9112 Operation & Installation ManualPage 25© 1993 Radionics74-06144-000-C 2/96Programmable Power Outputs Terminals 6 7 8ProgrammingThe power ou

Page 19 - Power Supply

D9112 Operation & Installation ManualPage 2674-06144-000-C 2/96© 1993-1996 RadionicsTerminals 6 and 7Terminals 6 (relay A) and 7 (relay B), provi

Page 20 - Secondary Power Terminals 4 5

D9112 Operation & Installation ManualPage 27© 1993 Radionics74-06144-000-C 2/96Telephone ConnectionsRegistrationThe Radionics D9112 Control/Comm

Page 21 - Battery Charging Circuit

D9112 Operation & Installation ManualPage 2874-06144-000-C 2/96© 1993-1996 RadionicsPhone Cord ConnectionConnect one end of a D161 (8') or D

Page 22 - Low Battery LED (Red)

D9112 Operation & Installation ManualPage 29© 1993 Radionics74-06144-000-C 2/96Phone Line Test PointsYou can attach a telephone test set tothe D

Page 23 - Power Outputs

D9112 Operation & Installation ManualPage 3© 1993 Radionics74-06144-000-C 2/96Part 68 (Continued)The telephone company may make changes in its f

Page 24 - Continuous Current Draw

D9112 Operation & Installation ManualPage 3074-06144-000-C 2/96© 1993-1996 RadionicsLINE SNIFFER SELECT8910REDGROUNDSTART EARTH GROUNDCOMMONGroun

Page 25 - Optional Relays Required

D9112 Operation & Installation ManualPage 31© 1993 Radionics74-06144-000-C 2/96Primary Phone Lines, Primary Phone NumbersDon’t confuse primary p

Page 26 - Terminal 8

D9112 Operation & Installation ManualPage 3274-06144-000-C 2/96© 1993-1996 RadionicsD128 Status LEDsFour LEDs mounted on the front edge of the D1

Page 27 - Telephone Connections

D9112 Operation & Installation ManualPage 33© 1993 Radionics74-06144-000-C 2/96On-Board PointsDescription Terminals 11 to 22The D9112 panel prov

Page 28 - Phone Line Monitor

D9112 Operation & Installation ManualPage 3474-06144-000-C 2/96© 1993-1996 RadionicsPoint ParametersYou can determine the condition of on-board p

Page 29 - Relay Installation

D9112 Operation & Installation ManualPage 35© 1993 Radionics74-06144-000-C 2/96Off-Board PointsPoint (ZONEX) Buss Terminals 23 to 28You can use

Page 30 - Operation

D9112 Operation & Installation ManualPage 3674-06144-000-C 2/96© 1993-1996 RadionicsListingsThe D8125 POPEX and D8127 POPIT modules are UL listed

Page 31 - Installing the D128

D9112 Operation & Installation ManualPage 37© 1993 Radionics74-06144-000-C 2/96Wiring the D8125 to the D9112 (Continued)Do not connect more than

Page 32 - D128 Status LEDs

D9112 Operation & Installation ManualPage 3874-06144-000-C 2/96© 1993-1996 RadionicsWiring POPITs to the Data Expansion LoopYou can connect up to

Page 33 - On-Board Points

D9112 Operation & Installation ManualPage 39© 1993 Radionics74-06144-000-C 2/96Wiring Data Expansion Loops to POPEX ModulesThere are two positiv

Page 34 - Point Response Time

D9112 Operation & Installation ManualPage 474-06144-000-C 2/96© 1993-1996 RadionicsTable of ContentsPower Outputs ...

Page 35 - Off-Board Points

D9112 Operation & Installation ManualPage 4074-06144-000-C 2/96© 1993-1996 RadionicsPoint AssignmentsSix switches on each POPIT assign the module

Page 36 - Wiring the D8125 to the D9112

D9112 Operation & Installation ManualPage 41© 1993 Radionics74-06144-000-C 2/96POPIT LabelsOff-board points are numbered 9 to 71 and 73 to 135.

Page 37 - Wiring POPITs to the D8125

D9112 Operation & Installation ManualPage 4274-06144-000-C 2/96© 1993-1996 RadionicsD8128A OctoPOPIT ModuleDescriptionThe D8128A OctoPOPIT Module

Page 38 - Combined

D9112 Operation & Installation ManualPage 43© 1993 Radionics74-06144-000-C 2/96Wiring OctoPOPITs to the D9112Follow the procedure below to wire

Page 39 - POPIT Sensor Loops

D9112 Operation & Installation ManualPage 4474-06144-000-C 2/96© 1993-1996 RadionicsLine TerminationIf there is no D8125 POPEX module connected t

Page 40 - Point Assignments

D9112 Operation & Installation ManualPage 45© 1993-1996 Radionics74-06144-000-C 2/96OctoPOPIT Sensor LoopsThe number normally-open and/or norma

Page 41 - Vertical Grid for POPEX #1

D9112 Operation & Installation ManualPage 4674-06144-000-C 2/96© 1993-1996 RadionicsTable 2:D8128A OctoPOPITSwitch SettingsNCI#215D8128ASwitches9

Page 42 - Installing the OctoPOPIT

D9112 Operation & Installation ManualPage 47© 1993-1996 Radionics74-06144-000-C 2/96Testing Off-board PointsUse the Service Walk Test item from

Page 43 - OctoPOPIT Sensor Loops

D9112 Operation & Installation ManualPage 4874-06144-000-C 2/96© 1993-1996 RadionicsOff-board RelaysD8129 OctoRelayThe D8129 OctoRelay allows you

Page 44 - Line Termination

D9112 Operation & Installation ManualPage 49© 1993-1996 Radionics74-06144-000-C 2/96Table 3: D8129 Switch SettingsD9112Relay NumberD8129 OctoRel

Page 45

D9112 Operation & Installation ManualPage 5© 1993 Radionics74-06144-000-C 2/96D8128A OctoPOPIT Module ... 42Listing ...

Page 46 - Sensor Loop

D9112 Operation & Installation ManualPage 5074-06144-000-C 2/96© 1993-1996 RadionicsInstallationDo not use the instructions packaged with the D81

Page 47 - Testing Off-board Points

D9112 Operation & Installation ManualPage 51© 1993-1996 Radionics74-06144-000-C 2/96D811 Arm Status Relay ModuleThe 811 Arm Status Relay Module

Page 48 - Off-board Relays

D9112 Operation & Installation ManualPage 5274-06144-000-C 2/96© 1993-1996 RadionicsWiring ConnectionsPower down the panel to connect D811 module

Page 49 - Page 49

D9112 Operation & Installation ManualPage 53© 1993-1996 Radionics74-06144-000-C 2/96Arming DevicesDescriptionCommand centers, maintained or mome

Page 50 - Wiring Connections

D9112 Operation & Installation ManualPage 5474-06144-000-C 2/96© 1993-1996 RadionicsInstallationConsult the D1255 Installation Instructions (74-0

Page 51 - Relay Output

D9112 Operation & Installation ManualPage 55© 1993-1996 Radionics74-06144-000-C 2/96D268/D269 Independent Zone ControlD279 Independent Zone Cont

Page 52

D9112 Operation & Installation ManualPage 5674-06144-000-C 2/96© 1993-1996 RadionicsKeyswitchDescriptionYou can connect a maintained or momentary

Page 53 - Arming Devices

D9112 Operation & Installation ManualPage 57© 1993-1996 Radionics74-06144-000-C 2/96Programmer and Accessory ConnectionsProgrammer Connector (J7

Page 54 - Page 54

D9112 Operation & Installation ManualPage 5874-06144-000-C 2/96© 1993-1996 Radionics5. Disconnect the programmer.6. Changes to some program param

Page 55 - D279 Independent Zone Control

D9112 Operation & Installation ManualPage 59© 1993-1996 Radionics74-06144-000-C 2/9635678910142Low BatteryLEDs Off When NormalEARTH GROUNDCOMMON

Page 56 - Keyswitch Operation

D9112 Operation & Installation ManualPage 674-06144-000-C 2/96© 1993-1996 RadionicsFigures and TablesFigure 1: D9112 System Configuration ...

Page 57 - Programmer Connector (J7)

D9112 Operation & Installation ManualPage 6074-06144-000-C 2/96© 1993-1996 RadionicsQuick Reference Terminal DescriptionTerminal Name Description

Page 58 - Programmer Access Reports

D9112 Operation & Installation ManualPage 61© 1993-1996 Radionics74-06144-000-C 2/96Installation Guide for UL and Fire ApplicationsListings and

Page 59 - D9112 Faceplate

D9112 Operation & Installation ManualPage 6274-06144-000-C 2/96© 1993-1996 RadionicsIntroductionThe D9112 System Chart references components eval

Page 60 - Terminal Name Description

D9112 Operation & Installation ManualPage 63© 1993-1996 Radionics74-06144-000-C 2/96Fire Applications (Continued)EnclosuresRadionics offers thre

Page 61 - Burglary

D9112 Operation & Installation ManualPage 6474-06144-000-C 2/96© 1993-1996 RadionicsSystem Chart2+ = Two or more required for this application. C

Page 62 - Fire Applications

D9112 Operation & Installation ManualPage 65© 1993-1996 Radionics74-06144-000-C 2/96System Wiring Diagram, Issue ADigital Alarm Communicator Tra

Page 63 - Enclosures

D9112 Operation & Installation ManualPage 6674-06144-000-C 2/96© 1993-1996 RadionicsCurrent Rating Chart for Standby Battery CalculationsAC Power

Page 64 - System Chart

D9112 Operation & Installation ManualPage 67© 1993-1996 Radionics74-06144-000-C 2/96Standby Battery RequirementsHousehold Burglary and Commercia

Page 65 - Page 65

D9112 Operation & Installation ManualPage 6874-06144-000-C 2/96© 1993-1996 RadionicsStandby Battery Calculation forNFPA 72 Fire Alarm Application

Page 66 - Page 66

D9112 Operation & Installation ManualPage 69© 1993-1996 Radionics74-06144-000-C 2/96Remote Station or Auxiliary SystemsRemote Station or Auxilia

Page 67 - Standby Battery Requirements

D9112 Operation & Installation ManualPage 7© 1993 Radionics74-06144-000-C 2/96IntroductionD9112D8128 COctoPOPIT combines8 POPIT Points in one mo

Page 68 - Current Chart First

D9112 Operation & Installation ManualPage 7074-06144-000-C 2/96© 1993-1996 RadionicsTroubleshooting GuideIntroductionRadionics provides this guid

Page 69 - Page 69

D9112 Operation & Installation ManualPage 71© 1993-1996 Radionics74-06144-000-C 2/96SERVC AC FAIL - AC Power FailedAn interruption of AC Power

Page 70 - Troubleshooting Guide

D9112 Operation & Installation ManualPage 7274-06144-000-C 2/96© 1993-1996 RadionicsPhone Line TroublePhone line problems that are not corrected

Page 71 - Page 71

D9112 Operation & Installation ManualPage 73© 1993-1996 Radionics74-06144-000-C 2/96Communications FailureThe D9112 goes into Communications Fai

Page 72 - Symptom Diagnosis Remedy

D9112 Operation & Installation ManualPage 7474-06144-000-C 2/96© 1993-1996 RadionicsCommunications Failure (Continued)Symptom Diagnosis RemedyThe

Page 73

D9112 Operation & Installation ManualPage 75© 1993-1996 Radionics74-06144-000-C 2/96Problems with PointsIf you incorrectly set the switches on a

Page 74

D9112 Operation & Installation ManualPage 7674-06144-000-C 2/96© 1993-1996 RadionicsProblems with Points (Continued)NCI #215Symptom Diagnosis Rem

Page 75

D9112 Operation & Installation ManualPage 77© 1993-1996 Radionics74-06144-000-C 2/96Problems with Points (Continued)Symptom Diagnosis RemedyAll

Page 76 - NCI #215

D9112 Operation & Installation ManualPage 7874-06144-000-C 2/96© 1993-1996 RadionicsProblems with the D8125 POPEX Data Expansion LoopsEMI (Electr

Page 77

D9112 Operation & Installation ManualPage 79© 1993-1996 Radionics74-06144-000-C 2/96Checking Shielded CableIf improperly installed, shielded cab

Page 78 - Metering the Loops

D9112 Operation & Installation ManualPage 874-06144-000-C 2/96© 1993-1996 RadionicsAreas and AccountsThe D9112 supports up to eight separate area

Page 79 - EMI on Long Wire Runs

D9112 Operation & Installation ManualPage 8074-06144-000-C 2/96© 1993-1996 RadionicsProblems with Command CentersSymptom Diagnosis RemedyCommand

Page 80

D9112 Operation & Installation ManualPage 81© 1993-1996 Radionics74-06144-000-C 2/96Battery and Power ReportsYou can program the D9112 to transm

Page 81 - Watchdog Reset Reports

D9112 Operation & Installation ManualPage 8274-06144-000-C 2/96© 1993-1996 RadionicsOverloaded Power SupplyIf the load on the D9112's power

Page 82 - Overloaded Power Supply

D9112 Operation & Installation ManualPage 83© 1993-1996 Radionics74-06144-000-C 2/96Service Walk TestThe Service Walk Test differs from the stan

Page 83 - Service Walk Test

D9112 Operation & Installation ManualPage 8474-06144-000-C 2/96© 1993-1996 RadionicsFigure 23: Service Walk Test Flow Chart(Text displays 60 sec

Page 84 - (Text displays 60 seconds)

D9112 Operation & Installation ManualPage 85© 1993-1996 Radionics74-06144-000-C 2/96Command 5 7 Toggles Default Idle TextCommand 5 7 allows tech

Page 85 - 9112 REV # # - # #

D9112 Operation & Installation ManualPage 8674-06144-000-C 2/96© 1993-1996 RadionicsFire and Fire/Burglary SystemsTo comply with UL 985 and 864 l

Page 86 - Specifications

D9112 Operation & Installation ManualPage 87© 1993-1996 Radionics74-06144-000-C 2/96SDI BusSDI Bus A (+): 9 VDC (15,000' max)SDI Bus B (-):

Page 87 - Page 87

D9112 Operation & Installation ManualPage 9© 1993 Radionics74-06144-000-C 2/96Event MemoryThe D9112 uses event memory to store events for each a

Comments to this Manuals