Bosch WORCESTER GREENSTORE User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
The control unit’s two methods to control
the heat pump
The control unit uses two different methods to control the heat pump.
These two methods are A or B, as below:
A: Control with outdoor sensor
A sensor is installed outside on a North facing wall of the house. Control
with an outdoor sensor means that the heat pump automatically regulates
the heating in the house depending on the outdoor temperature. If the
outdoor temperature drops, the radiators/underfl oor heating inside the
house will become warmer.
The user determines the response from the heat pump in relation to
the outdoor temperature, with the help of a number of settings such as
selecting the heat curve on the control unit. Further explanation is given
later in this manual.
B: Control with outdoor sensor supplemented with
room sensor
Control with an outdoor sensor supplemented with a room sensor means
that you also place a sensor in a reference position inside the house. This is
connected to the heat pump and provides the control unit with information
about the room temperature. The signals affect the control unit’s settings
(heat curves) and ensure the heat pump gives the best possible energy
savings.
It is only the room where the room
sensor is located that can infl uence
regulation of the temperature.
Note
Rego 637W Control unit
Note
The room sensor infl uence is inhibited
2 hours after using clock setting for
the heating, or any type of external
control of the heat pump.
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 25 26

Comments to this Manuals