Walk Test (CMD + 4 + 4)
Description
Use this function to test keypads, detection devices,
and sounders (both interior and exterior) to be certain
they function properly. You can review untested points
at your keypad to help pin-point any problems.
You cannot arm your system while in the walk test
mode, and no alarm reports are sent to your security
company unless a 24-hr point is activated (such as fire
or panic).
Upon initiation, the walk test tests the burglary bell
pattern on the bell output and rings the keypad
burglary bell for 2 sec. The AC power is disabled for 4
min in order to test the system’s battery power.
If the battery cannot maintain the system for the four-
minute period, the keypad appears to power off. If this
happens, contact your security company. At the end of
the four-minute period, AC is returned to the system
and the control panel restores. To test individual
detection devices, simply activate sensors and open
protected doors and windows one-at-a-time. As each
detection device is faulted, the keypad emits a brief
tone and the display indicates for 60 sec that the point
has been tested. This verifies that each detection device
is working properly.
Using Walk Test
1. Ensure your keypad shows idle text.
2. Press the CMD button. The display shows
*System Command*.
3. Press the 4 button and then the 4 button.
If you prefer, you might use the function
list in place of Steps 2 and 3 to initiate
this function.
Press the Menu button to enter the
function list.
Press the Next button repeatedly.
When you reach the Walk Test button,
press it.
4. The burglary bell sounds for 2 sec. When the
display shows ### points remain to be tested
(### is the number of points) you can begin.
Test each point by first opening and then closing
the door or window, or activating the other
detection device types.
Check the display after testing each point. For
interior points, walking past the device once is
sufficient. If any point will not test correctly,
contact your security company for service.
5. During the Walk Test you might want to refer to
the points that remain untested by pressing the
View untested pts button.
The display shows ### pts untested.
Press the Next Pt or Prev Pt
buttons to refer to
information about specific points that have not
yet been tested.
6. Move through this list by pressing the Next Pt
button.
The display changes to show the information for
that point.
Press the Exit button to return to the ### points
remain to be tested screen before continuing
with the walk test.
Page view 20