AMAX panel 2000 / AMAX panel 2000 EN Fault and Tamper Description | en 11
Robert Bosch Engineering and Business Solutions LimitedQuick Reference Guide F.01U.241.128 | V2 | 2011.11
3 Fault and Tamper Description
Whenever a system fault or a tamper condition occurs, the FAULT or MAINS indicator flashes
and the keypad beeps.
To enter fault and tamper condition analysis mode to determine a system fault or tamper
condition:
1. Enter your Code and [2] and press [#] two beeps sound.The FAULT indicator remains lit
and the STAY and AWAY indicators flash. The lit zone indicators indicate the type of fault
or tamper condition that occurred.
2. For multi-level menu, enter the corresponding number to enter the submenu, press [ 0 ]
key to return to the main menu.
3. To exit from Fault and Tamper Analysis Mode, press [#] . The STAY and AWAY indicators
are extinguished and the FAULT indicator remains lit, and the keypad stops the beep.
When a new fault or tamper occurs, the FAULT indicator flashes again and the keypad beeps.
The FAULT indicator gets extinguished once all faults are restored.