14 en | Programming sheets AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.128 | V2 | 2011.11 Quick Reference Guide Robert Bosch Engineering and Business Solutions
Example: For IP Address for receiver 128.73.168.7, communication port 7700, program as:
128 073 168 007 07700
4.1.2 Domestic programming
4.2 System Report Options Programming
System sends reports to Receiver 1-4 according to system status report options. The
locations for the reports are 137-144.
4.2.1 Report Options
NOTICE!
Programming option anti-replay, acknowledge wait time and pulse interval time are only used
in Bosch network format.
Address 120–135
Preset values 15 (if the first digit input is 15 this function is prohibited)
Digit Program input keys Digit Program input keys
0088
1199
22* 11
33#12
4 4 Wait 4 seconds 13
551515
66
77
Location 137-144 Location Default
Zone Restore Report Options (Alarm restore, fault restore,
bypass restore)
137 0
Arm/Disarm report option in AWAY Mode 138 6
Arm/Disarm report option in STAY Mode 139 6
System Status Report Options (Zone fail, comm. fail,
telephone line fail, AC fail, low battery...etc.)
140 6 EN=1/
5/6/7
Keypad panic report 141 0
Keypad fire report 142 0
Keypad medical report 143 0
Test report options 144 6 EN=1/
5/6/7
Zone Status Reporting Options
0 No zone status report allowed
1 Report to Receiver 1
2 Report to Receiver 2
3 Report to Receiver 3
4 Report to Receiver 4