AMAX panel 2000 / AMAX panel 2000 EN Programming sheets | en 17
Robert Bosch Engineering and Business Solutions LimitedQuick Reference Guide F.01U.241.128 | V2 | 2011.11
4.3.16 AC Fault Detect time
4.3.17 Battery Detect time
4.3.18 Event Record Count Per Set/Unset Period
4.3.19 Beep for Warning Devices
4.4 Zone Programming
Location 189-190 Location Default
0-60 Minutes 189-190 10
Location 191 Location Default
1-15 min 191 1 EN=15
Location 192 Location Default
3-10 192 3
Location 193 Location Default
0=Disable 1=Enable 193 0
Location 210-289
Zone Location Default
Zone #01
Zone Type (Refer to zone type option) 210 3
Zone Bypass (Disable=0, Enable=1) 211 1
Forced Arming (Disable=0, Enable=1) 212 1 EN=0
Silent Alarm (Enable=1, Disable=0) 213 0 EN=0
Zone alarm lock out time (Disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=4)
214 0
Support Detector Tamper (Disable=0, Enable=1) 215 1
Zone alarm report (Refer to zone report option) 216 6 EN=1/
5/6/7
Zone Chime Mode (Enable=1, Disable=0) 217 0
Reserved 218-219 0
Zone #02
Zone Type (Refer to zone type option) 220 1
Zone Bypass (Disable=0, Enable=1) 221 1
Forced Arming (Disable=0, Enable=1) 222 1 EN=0
Silent Alarm (Enable=1, Disable=0) 223 0 EN=0
Zone alarm lock out time (disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=3)
224 0
Support Detector Tamper (Disable=0, Enable=1) 225 1
Zone alarm report (Refer to zone report option) 226 6 EN=1/
5/6/7
Zone Chime Mode (Enable=1, Disable=0) 227 0
Reserved 228-229 0