22 en | Programming sheets AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.128 | V2 | 2011.11 Quick Reference Guide Robert Bosch Engineering and Business Solutions
Table 4.1 Output Events Option
4.6 Installer/User Code Programming
Each installer/user code unit contains up to 4 digits. Each digit range is 0-9. Default first digit
as data 15 means Not Used. Other data are not permitted.
4.6.1 Installer code #0
Installer Code is used to program the system.
Event Type Description
0 No output activate for the events
1 System Disarmed
2 System Armed
3 System Alarm
4 Entry/Exit Delay Warning
5 Telephone Line Fail
6AC Lost
7 Battery Low
8RF Power Fault
9TAMPER
10 External Fault
11 All Faults
12 Away armed
13 Stay armed
14 Reset
15 24h Alarm
Location 425-428 Location Default
425 1
426 2
427 3
428 4