AMAX panel 2000 / AMAX panel 2000 EN FAQs | en 27
Robert Bosch Engineering and Business Solutions LimitedQuick Reference Guide F.01U.241.128 | V2 | 2011.11
After an auxiliary
power source short
circuit, system cannot
be restored.
Restart the AC power supply and battery
After changing the
battery, a battery error
still shows.
When the system is armed or every 4 hours, it checks the
battery, so it may be necessary to wait before the battery error
is cleared
New batteries may require charging before they reach 12 V
When there is an
alarm, the system does
not dial.
Check whether the communications were programmed to
disable the dial function (telephone number and
communication format must be programmed)
Cannot remotely alarm. Check whether this function has been programmed (address
152 cannot be 0)
Central software
cannot be remotely
programmed and
controlled.
Check whether this function has been programmed (address
152 and 153 cannot be 0)
Using PSTN/personal
telephone alarm the
communication is
occasionally incorrect.
The telephone network uses an extension system; it is
necessary to add a delayed dial
The telephone network also supports ADSL; system must be
connected after the ADSL wave filter