Bosch DVA-12T Installation Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
RAID Subsystem DVA-12T | Installation Manual Specifications | en 45
Bosch Security Systems F.01U.027.798 | V1 | 2006.06
7.3 Drive Tray Specifications
7.4 Power Supply Specifications
7.5 Cooling Module Specifications
7.6 RAID Management
Specification
Height 28mm
Width 110mm
Depth 218.92mm
Key Lock Yes
Specification
Nominal Power 350W
DC Output 12.0V: 25A
5.0V: 25A
3.3V: 20A
Input Frequency 47 to 63Hz
AC Input 115VAC @ 6A or 240VAC @ 3A with PFC
Power Factor Correc-
tion
Yes
Hold-up Time At least 16ms at 115/230VAC full load after a loss of AC input
Over-temperature
Protection
Auto shutdown when lost cooling or exceeded ambient tempera-
ture; over-voltage protection is also available.
Cooling Fans Two fans for each unit (inside PSU)
Specification
Speed High or low rotation speed controlled by firmware
Max. Air Flow (each
module)
High speed: 31.8 CFM
Low speed: 20.1 CFM
Input Power 9/3.12W max.
Rated Voltage DC 12V
Temperature Operating: -10 to +60ºC
Storage: -20 to +70ºC
Specification
Configuration
Text-based firmware-embedded utility over RS-232C
through the included audio jack-to-DB-9 serial cable
The RAIDWatch Manager program using Ethernet
connection
Performance Monitoring Yes
Remote Control and
Monitoring
Yes
Page view 44