Bosch EX65 Instruction Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
EX65 Explosion-protected Illuminator Planning | en 15
Bosch Security Systems, Inc. Instruction Manual F.01U.162.949 | 1.0 | 2011.03
Figure 3.3 Bottom View
3.2 Initial Preparations
Determine the operating voltage at the installation site. The circuit board automatically
configures for 12 VDC or 24 VAC operation. The unit can receive an input voltage range of
10.5 VDC to 40 VDC or 12 VAC to 28 VAC without damage, but it is recommend to stay
within the voltage range specified in Section 1.6 Explosion Protected Certifications.
All units have been tested prior to shipment. It is advisable to check the unit’s operation
before installation.
Ø
6.6
0.26
71°
60.0
2.36
3/4-in. NPTX 4
CAUTION!
It is recommended that the installer wear an ESD strap or discharge any static electricity to
ground before handling any electronic components.