EX65 Explosion-protected Illuminator Connections | en 17
Bosch Security Systems, Inc. Instruction Manual F.01U.162.949 | 1.0 | 2011.03
5 Connections
All required connections are accessible by removing the end cap conveniently located in the
rear of the EX65.
5.1 Power Cable Requirements
Connect power from a 12 - 24 VAC or 12 - 24 VDC class 2 power supply. Use AWG 16 to 22
stranded wire or AWG 16 to 26 solid wire; cut back 5 mm (0.2 in.) of insulation.
5.1.1 Wire Distance Guide
This table lists the maximum wire distances for 14, 16, and 18 AWG wires connected to a
24 VAC illuminator.
5.2 Telemetry Cable Requirements
The EX65 terminal block contains two terminals for telemetry cables from a remote
illuminator control device.
NOTICE!
Take care not to drop the end caps to prevent damage to the cap threads.
WARNING!
Before proceeding, disconnect the power from the power supply cable. Ensure that the
voltage of the unit matches the voltage and type of the power supply being used.
Cable size Stranded wire: AWG 16 to 22
Solid wire: AWG 16 to 26
Cable shape Round
Conductors 2-conductor version
Environmental Outdoor rated
Watts 14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
LED-658 Series
LED-659 Series
37 133 m
(438 ft)
84 m
(276 ft)
53 m
(173 ft)
Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of
insulation
Telemetry in Normally Open connection, remove jumper to use external
control device