Bosch DIP-7082-8HD Installation Manual

Browse online or download Installation Manual for Servers Bosch DIP-7082-8HD. Bosch DIP-7082-8HD Installation manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - DIVAR IP 7000 2U

DIVAR IP 7000 2UDIP-7080-00N, DIP-7082-8HD en Installation Manual

Page 2

ChassisThe chassis includes 8 hard drive bays and supports a 2U backplane, 3 fans and two powersupplies.BackplaneEach chassis comes with a 2U backplan

Page 3 - Table of contents

Front view:152634 71 Power Failure 5 Power2 Overheat/Fan Fail 6 Reset3 NIC1/NIC2 7 Power on/off4 HDD Rear view:26715341 2x mains connection 100 –

Page 4

– Reset: The reset button is used to reboot the system.– Power: The main power switch is used to apply or remove power from the powersupply to the se

Page 5 - Safety precautions

– Green: Each Serial ATA drive carrier has a green LED. When illuminated, this green LED(on the front of the SATA drive carrier) indicates drive activ

Page 6 - Electrical safety precautions

Chassis setup and maintenanceThis chapter covers the steps required to install components and perform maintenance on thechassis.!Caution!Review the wa

Page 7 - Operating precautions

Installing hard drivesThis chapter describes the removing and installing of hard drives.Removing hard drive traysThe drives are mounted in drive carri

Page 8 - FCC and ICES compliance

Installing a hard driveThe drives are mounted in drive carriers.To install a hard drive to the hard drive carrier:1.Remove the screws securing the du

Page 9 - System overview

Notice!We recommend using the respective Bosch hard disk drives. The hard disk drives as one ofthe critical component are carefully selected by Bosch

Page 10 - System interface

Replacing or installing a DVD-RWThe chassis model includes a pre-installed slim DVD-RW drive.1 DVD-RW 2 Front Port Panel To replace or install a DVD d

Page 11 - Control panel buttons

1 DVD-RW 2 Front Port PanelTo replace or install the front port panel:1.Turn off and unplug the unit.2. Remove the chassis cover.3. Disconnect the pow

Page 13

To install the air shroud:4 Place air shroud in the chassis. The air shroud fits behind the two fans closest to thepower supply. Note: If a 16 DIMM (1

Page 14 - Chassis setup and maintenance

11 Release Tab!Warning!The fans might still be turning when you remove the fan assembly from the chassis. Keepfingers, screwdrivers, and other objects

Page 15 - Installing hard drives

LED status:–Amber lighted LED: The power supply is off.– Green lighted LED: The power supply is operating.!Warning!Redundant power suppliesThis unit m

Page 16 - Installing a hard drive

Replacing the power distributorRedundant server chassis that are 2U or greater require a power distributor. The powerdistributor provides failover and

Page 17 - Installing a fixed hard drive

Rack installationThis chapter provides a quick setup checklist to get your chassis up and running. Followingthese steps in the order given should enab

Page 18

– If the rack is provided with stabilizing devices, install the stabilizers before mounting orservicing the unit in the rack.–This unit should be moun

Page 19 - Installing the air shroud

Rack mounting instructionsThis section provides information on installing the chassis into a rack unit. There are a varietyof rack units on the market

Page 20 - Replacing the system fans

4. Separate the inner rail extension from the outer rail assembly.Installing the inner railsThe chassis includes a set of inner rails in two sections:

Page 21 - Power supply

To install the outer rails to the rack:1.Secure the back end of the outer rail to the rack, using the screws provided.2. Press the button where the tw

Page 22 - Replacing the power supply

Installing the chassis into a Telco rackTo install the chassis into a Telco type rack, use two L-shaped brackets on either side of thechassis (four in

Page 23

Table of contents1Safety precautions 51.1 General safety precautions 51.2 Electrical safety precautions 61.3 ESD precautions 71.4 Operating precaution

Page 24 - Rack installation

System setup - first stepsThe following installation directive provides information on Installation and Configuration.DIVAR IP systems are based on Wi

Page 25 - Rack mounting considerations

8. After entering the password, a message is displayed that you must change the passwordbefore logging on the first time. To confirm, click OK.9.Chang

Page 26 - Rack mounting instructions

– configuring external storage devices–all advanced configurations beyond a basic setup (maps or alarms, for example)For these tasks refer to the Bosc

Page 27 - Installing the inner rails

Network settings pageYou configure the network settings of the operating system.As soon as you click Next button, the settings are activated.If you ha

Page 28

Time settings pageYou configure the time settings of the operating system. 34 en | System setup - first steps DIVAR IP 7000 2U2013.09 | V2 | DOC Inst

Page 29 - Turning on the system

Video settings pageThis page displays the devices and services that are included in the latest saved configuration.You can import a configuration. DI

Page 30 - System setup - first steps

Device selection pageThis page displays all video devices that are not included in the latest saved configuration.Deselect the devices that should not

Page 31 - Using Configuration Wizard

Device passwords pageThis page is used to authenticate password protected devices. This can either be done for allcameras at once (if passwords are id

Page 32

Recording profile pageFor different profile assignments to different cameras you must execute Configuration Wizardmultiple times.Note:Before selecting

Page 33

The default schedule is used for all recording profiles.The Day schedule is active from 8 a.m. until 6 p.m., Monday through Friday.The Night schedule

Page 34 - Time settings page

4.3.4 Installing the chassis into the rack 284.3.5 Installing the chassis into a Telco rack 294.4 Turning on the system 295System setup - first steps

Page 35 - Video settings page

Add storage pageThis page allows the addition of additional iSCSI storage devicesFor limitations, refer to the datasheet available in the online catal

Page 36 - Device selection page

User accounts pageYou can add users and passwords. Use Configuration Client to add user groups and to changepermissions. DIVAR IP 7000 2U System setu

Page 37

Finish configuration pageAfter clicking Save and activate the configuration is activated.After successful activation the Activate Configuration page i

Page 38

Using Bosch VMS Operator ClientUse Bosch VMS Operator Client to verify the live, recording and playback functionality ofDIVAR IP.To verify live image

Page 39

Recovering the unitSystem recovery optionsFollowing procedure describes how to restore the factory default image.To restore the unit to factory defaul

Page 40

Basically, the RAID controller writes the raidconfiguration - information (COD = configuration-on-disk) in an only field on each disk managed by the c

Page 41 - User accounts page

The data area can only be deleted with a "fast" or "full" initialization; as long as an initializationis omitted, the OS file syst

Page 42

How to use the Event Viewer in the Controller Bios UtilityClick on an event in the main screen; choose "physical" or "virtual drive&quo

Page 43

The VD event reports first a degraded state, then an offline state. The "first failed" disk wasthe rebuilding PD4. When PD6 failed, the rebu

Page 44 - Recovering the unit

===========None seqNum: 0x0000188bTime: Mon Jul 19 13:52:41 2010 Code: 0x00000070Class: 1Locale: 0x02Event Description: Removed: PD 06(e0xfc/s6)Event

Page 45

Safety precautionsObserve the safety precautions in this chapter.General safety precautionsFollow these rules to ensure general safety:–Keep the area

Page 46

Event Data:===========Target Id: 1Useful commands: MegaCli -AdpEventLog -GetEvents -info -f info.txt -aALL(but a large text file) MegaCli -AdpEventLog

Page 47

Select one of the two configurations and click Preview.All disks are seen, but configuration is marked as not importable; click Cancel and viewConfigu

Page 48

Before clear foreign configuration, 2 disks were missing, two were foreign. After clear, theforeign disks now are shown as unconfigured.Use the event

Page 49

Now in Logical View we see this disk marked as offline; click on the disk to get in PD menu.Click on "Make online" and "go".Now in

Page 50

Foreign configuration disk appears in the Windows GUI after bootingThe RAID is degraded. Topology error is shown. Right-click Megaraid Controller in t

Page 51

MegaCLI Commandline Utility[-Silent] [-AppLogFile filename] [-NoLog] [-page [N]][-] is optional.N - Number of lines per page. MegaCli -vMegaCli -help|

Page 52

1=Disable Cache Bypass.MegaCli -AdpSetProp -LoadBalanceMode -val -aN|-a0,1,2|-aALLval - 0=Auto Load balance mode.1=Disable Load balance mode.MegaCli -

Page 53

MegaCli -PDMakeGood -PhysDrv[E0:S0,E1:S1,...] | [-Force] -aN|-a0,1,2|-aALLMegaCli -PDMakeJBOD -PhysDrv[E0:S0,E1:S1,...] -aN|-a0,1,2|-aALLMegaCli -PDHS

Page 54

[CachedBadBBU|NoCachedBadBBU][-strpszM][-szXXX[-szYYY ...]][-AfterLdX]|[FDE|CtrlBased] -aNMegaCli -CfgAllFreeDrv -rX [-SATAOnly] [-SpanCount XXX] [WT|

Page 55 - MegaCLI Commandline Utility

MegaCli -PDCpyBk -Stop|-ShowProg|-ProgDsply -PhysDrv[E0:S0] -aN|-a0,1,2|-aALLMegaCli -PDInstantSecureErase -PhysDrv[E0:S0,E1:S1,...] | [-Force] -aN|-a

Page 56

!Warning!Lithium battery:Batteries that have been inserted wrongly can cause an explosion. Always replace emptybatteries with batteries of the same ty

Page 57

Additional documentation and client softwareDocumentation for Bosch Security System products can be found as follows:4 www.boschsecurity.com > sele

Page 58

AppendicesThis chapter gives information for supporting and troubleshooting. MotherboardAll graphics shown in this chapter were based upon the latest

Page 59

Motherboard component overviewFigure 8.2: Motherboard – component overviewX8SIL/X8SIL-F/X8SIL-V jumpersNumber Jumper Description Default38 JPUSB1 BP U

Page 60

X8SIL/X8SIL-F/X8SIL-V headers/connectorsNumber Connector Description4,16 COM1/COM2 COM1/2 Serial connection headers33,32,27,23,7 Fans 1~5 System/CPU f

Page 61 - Appendices

Motherboard featuresCPU Single Intel Xeon 3400 series processor in an LGA1156 socket.Memory Four (4) 240-pin, DDR3 SDRAM DIMM sockets with support for

Page 62

Two (2) USB ports on the rear IO panelFour (4) USB header connectors for front accessOne (1) Type A internal connectorKeyboard/MousePS/2 Keyboard/Mous

Page 63

Drivers and software for Intel 3400/3420 chipset utilitiesOther ROHS 6/6 (Full Compliance, Lead Free)Dimensions Micro ATX form factor, 9.6" x 9.6

Page 64 - Motherboard features

better performance than comparable systems. The X8SIL/X8SIL-F/X8SIL-V also features a TCOtimer (to enable the system to recover from a software/hardwa

Page 65

the system to keep the required circuitry "alive". In case the system malfunctions and youwant to turn off the power, just press and hold th

Page 66 - Chipset overview

For the X8SIL/X8SIL-F/X8SIL-V motherboard, iSCSI is supported on LAN 1. This can beenabled through the BIOS: Advanced => PCI/PnP Configuration =>

Page 67 - Power configuration settings

– Use only one hand when working with powered-on electrical equipment. This is to avoidmaking a complete circuit, which will cause electrical shock. U

Page 70

Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanywww.boschsecurity.com© Bosch Sicherheitssysteme GmbH, 2013

Page 71

Note:Please handle used batteries carefully. Do not damage the battery in any way. A damagedbattery may release hazardous materials into the environme

Page 72

System overviewDIVAR IP 7000 is an affordable, simple and reliable all-in-one recording, viewing andmanagement solution for network surveillance syste

Comments to this Manuals