18 TSTBM3H2CPH6W-A Technician Setup Menu
Tech Setup Step (Continued from the previous page)
LCD will show Adjustment Options
Factory
Default
Settings
Gas
Auxiliary for
Heat Pump
(only
available in
HP mode)
This option will turn the heat
pump off 45 seconds after the
auxiliary heat relay turns on.
For 2 heat applications, the
rst stage will turn off 45
seconds after the auxiliary
stage turns on.
For 3 heat applications, the
rst and second stage will
turn off 45 seconds after the
auxiliary stage turns on.
Selectable on or off.
This option should be ON for
applications that uses a gas furnace
for auxiliary heat.
This is an extremely important feature
to set if utilizing a gas furnace.
Operation of the gas furnace while the
compressor is running will overheat
and damage the compressor.
This feature is disabled when a
TSTBM-OTS-TW-A is connected. See
Balance Point feature setup.
OFF
Cooling Fan
Delay
(seconds)
The cooling fan delay setting
will delay the fan from
coming on in cool mode
and keep running after the
compressor shuts off for a
short time to save energy in
some systems.
You can select the Cooling Fan Delay
from OFF, 15, 30, 60 or 90 seconds.
If 15, 30, 60 or 90 is selected the fan
will not turn on for that many seconds
when there is a call for cool and
will run for that many seconds after
satisfying a call for cool.
This feature is disabled when a
TSTBM-OTS--TW-A is used. See
Balance Point feature setup.
OFF
Outdoor
Sensor
Enables the use of an outdoor
sensor TSTBM-OTS--TW-A.
Connecting a TSTBM-OTS-
-TW-A allows for a balance
point setting.
Selecting YES requires
the TSTBM3H2CPH6W-A
master thermostat to be
powered with 24V on C and R
terminals.
See TSTBM-OTS--TW-A user
guide for more information.
When NO is selected the thermostat
is unable to connect to an outdoor
remote sensor TSTBM-OTS--TW-A.
When YES is selected the thermostat
is able to connect to an outdoor
remote sensor TSTBM-OTS--TW-A.
Press and hold connect button
on TSTBM-OTS--TW-A until the
TSTBM3H2CPH6W-A says FOUND
OUTDOOR on display.
NO
Caution
Connect an optional TSTBM-OTS--TW-A
outdoor remote temperature sensor to
enable the balance point tech setup option.
Caution
Up to four TSTBM-RRS--TW-A indoor temperature
sensors can be connected to one
TSTBM3H2CPH6W-A thermostat.
This allows for 5 sensing points (zones). For Example:
The local ( TSTBM3H2CPH6W-A) plus four TSTBM-
RRS--TW-A sensors enables 5 sensing points.
See the tech setup menu below to activate this feature.
Reference the installation manual for the TSTBM-RRS--
TW-A remote room sensor for detailed instructions on
connection and setup.