Page view 10
3/4” PVC pipe
Casing Dimensions
Connection Measurements
Outdoor clearances to doors & windows
Outdoor installations should have the minimum clearances
shown below to ensure that flue exhaust cannot enter into
surrounding buildings.
Pipework Connections
A Hot water outlet 3/4”
B Cold water inlet 3/4”
C Gas connection 3/4”
D Condensate outlet 1/2”
Connection dimensions
condensate drain from freezing by installing insulation,
heat tape or electric heaters.
Important points to consider when siting a condensate
drainage pipe
3 Ensure the plastic piping is no smaller than ¾” in
diameter
3 Use plastic pipe. Do not use steel, black iron or other
corrodible material
3 Keep the length of the drainline as short as possible
3 Horizontal runs must be sloped 1/50 downwards
towards the drain
3 The drain end should not be submerged in water or
blocked in any way
Condensate pipework
This system is supplied with a pre-installed condensate
neutralisation system. This neutraliser will remove any
acidity that is present in the condensate. This means that
no further steps are required to treat the condensate,
unless local laws specify otherwise.
In colder areas, considerations should be taken in order
to stop the drainline from freezing. If the temperature is
likely to drop below 0°C, take measures to prevent the
A
B
C
D
Technical & Specification Information – Bosch 32 Series Water Heaters
|
11