Bosch BC3200RA5 Service Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
Bosch 32C water heater
Flueing configurations
The Bosch 32C water heater uses the 100mm
polypropylene flue system supplied by Bosch.
The maximum flue length is 13m. For every 90 degree
elbow subtract 2m from the maximum length. For every
45 degree elbow subtract 1m from the maximum length.
Available flue components
Components Part No. Description
BCVC-100C Stainless Steel Vent Cap
MG85176
PP extension pipe
100 x 500m
MG85177
PP extension pipe
100 x 1000mm
MG 85181
PP flue elbow, 90°,
100m diameter
MG85182
PP flue elbow, 45°, 100mm
diameter
MG84631
Wall bracket suitable
for 32C flueing
MG87930
Horizontal wall
terminal, PP & aluminum
100mm diameter
MG84862
Vertical roof terminal,
PP, 100/150mm dia,
incl air cover MG75439
MG27356
Sealing Ring, please note:
1 unit required for every
internal installation
The following considerations should be made when
planning the installation
3 Use only Bosch flue materials
3 Vertical sections of flue must be as short as possible
3 Maintain the same flue pipe diameter throughout the
entire flue
3 Ensure that connections are gas tight and will not leak.
Use heat resistant silicon sealant wherever necessary
3 Use a maximum of 1m straight pipe before the first elbow
Outdoor installation
Components
Part Numbers BCVC-100C
Maximum length (mm) & no. of components required
N/A 1
Standard internal horizontal flue assembly
Components
Part Numbers MG27356 MG85181
MG85176
MG85177
MG87930
Maximum length (mm) & no. of components required
11,000 1 1 1 or more 1
14
|
Technical & Specification Information – Bosch 32 Series Water Heaters
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 59 60