Page view 27
Bosch 32 & Bosch 32Q
Flueing configurations
The Bosch 32 and 32Q water heaters are flued by the
flue kits available. The vertical and horizontal flue kits
contain components required for most applications.
The maximum acceptable flue length is 13m. For every
90 degree elbow 2m should be subtracted from this
length. All internal gas water heaters must be flued and
installed with adequate ventilation in accordance with
AS/NZS5601.
Vertical Flue Kit
The vertical flue kit contains the following components
3 100mm gas cowl
3 1.5m x 100mm diameter gas flex (3 piece)
3 Flue pipe adaptor (3 pieces)
3 Support struts (2 pieces)
3 3m x 6mm condensation hose
Horizontal Flue Kit
The horizontal flue kit contains the following components
3 100mm diameter flexible flue, 5m long
3 Flue sleeve
3 Adjustable wall penetration sleeve (2 pieces)
3 Clamp
The following considerations should be made when
planning the installation
3 Vertical sections of flue must be as short as possible
3 Ensure the joins are gas tight and will not leak. Use
heat resistant silicon sealant wherever necessary.
3 Use a maximum of 1m straight pipe before the first
elbow
Available flue components
Components Part No. Description
KMVC-100 Vent Cap
FKV32LTR Vertical Flue Kit
FKH32LTR
SS flue elbow, 90°, 100m
diameter
Standard vertical flue kit
Part No 100mm FKV32LTR
Maximum length (mm) & no. of components required
9m 1 kit
Standard horizontal flue kit
Part No 100mm FKH32LTR
Maximum length (mm) & no. of components required
11m 1 kit
Outdoor installation
Components
Part Numbers KMVC-100
Maximum length (mm) & no. of components required
N/A 1