1
Installation/Operating Instructions
Invented for life
MODELS
Bosch 17e
Bosch 21e
Bosch 25e
Bosch 26e
(YS1770RA series, YS2170RA series, YS2670RABZ, YS2670RA series)
INSTALLATION MANUAL
This appliance must be installed in accordance with the manufacturer’s installation instructions, AS5601,
AS/NZS3500.4, AS3000 wiring regulations and all Local Building, Water and Gas fitting regulations.
To be installed and serviced only by an authorised person
This appliance is not suitable for use as a pool heater
The “authorised installing person” is responsible for :
1. Correct commissioning of this appliance.
2. Ensure unit performs to the specifications stated on the rating label.
3. Demonstrate operation of unit to customer before leaving.
4. Hand these instructions to customer.
Failure to install this appliance in accordance with these installation instructions may void warranty
SAR8512-7
Rev. 10/11
*SAR8512 C*
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - INSTALLATION MANUAL

1Installation/Operating InstructionsInvented for lifeMODELSBosch 17eBosch 21eBosch 25eBosch 26e(YS1770RA series, YS2170RA series, YS2670RABZ, YS2670RA

Page 2 - Page Number

10HOT WATER CONNECTION TO WATER HEATER.Refer to Technical Sheet for position of connection. The outlet connection is 20 mm (3/4"BSP) MALE thread,

Page 3 - Invented for life

11Installation/Operating InstructionsInvented for lifeTEMPERATURE SELECTOR PAD INSTALLATION DETAILSMain, Bathroom & Sub ControlSelect a suitable f

Page 4 - YS2170RA series 214

12Installation/Operating InstructionsInvented for lifeTEMPERATURE CONTROL OPERATIONTurn the main temperature selector ON by pressing the Operation swi

Page 5 - TECHNICAL DATA

13Installation/Operating InstructionsInvented for lifeSETTING THE TEMPERATUREUSE BRIDGES PROVIDEDUse the bridges provided to change the temperature as

Page 6 - APPLIANCE LOCATION

14Installation/Operating InstructionsInvented for lifeStep 2: Turn off power to unit.Step 3: Insert bridge into plastic clip between the controller t

Page 7 - COMPONENT DETAILS

15Installation/Operating InstructionsInvented for lifeUSER SAFETY INSTRUCTIONSPLEASE CAREFULLY READ THIS USER INSTRUCTION BEFORE USE.You have selected

Page 8 - • YS2670RA series, YS2670RABZ

16WATER QUALITYAll Bosch water heating appliances are constructed from high quality materials andcomponents and all are certified for compliance with

Page 9 - ISOLATING GATE VALVE

17Robert Bosch (Australia) Pty Ltd (Bosch)Manufacturer’s Warranty(Applicable for purchases from 1 January 2012)All Bosch hot water units are carefully

Page 10 - ELECTRICAL CONNECTION

18(d) Repair or replacement of the hot water unit or any parts under this warranty does notlengthen or renew the warranty period. (e) This warranty i

Page 11 - PRE-SET TEMPERATURE

2Page NumberINTRODUCTION 3DIMENSIONS 4TECHNICAL DATA 5APPLIANCE LOCATION 6COMPONENT DETAILS 7GAS CONNECTION 9COLD WATER CONNECTION 9HOT WATER CONNECTI

Page 12 - BURNER PRESSURE ADJUSTMENT

3This Bosch water heater is an external, electronically controlled gas water heater.This Bosch appliance is supplied set to operate without temperatur

Page 13 - SETTING THE TEMPERATURE

4DIMENSIONS YS1770RA series, YS2170RA seriesInstallation/Operating InstructionsInvented for life510∼51248445204875421010120608413397403710940573110851

Page 14 - Modulation

5Installation/Operating InstructionsInvented for lifeTECHNICAL DATA Nominal hourly gas consumption by proportional gas control:17e21e26e135 Mj/hr170 M

Page 15 - SERVICING AND MAINTENANCE

6Use as a guide only. Refer to AS5601 or local gas fitting rules for specific locationsT=Flue terminalI=Mechanical air inletM=Gas meterW=WindowShaded

Page 16 - ATER QUALITY

7Installation/Operating InstructionsInvented for lifeCOMPONENT DETAILSEarth leakage breakerFlue terminalAntifrost heaterHigh-limit switchEmpty heating

Page 17

8Installation/Operating InstructionsInvented for lifeHot-water temperature change connectorPrinted circuit boardGas solenoid valve setIgnition plugRem

Page 18

9Installation/Operating InstructionsInvented for lifeGAS CONNECTION(1) Fit a union to the water heater gas inlet for easy connection and removal. Th