Bosch C1210ES Specifications

Browse online or download Specifications for Water heaters & boilers Bosch C1210ES. Bosch C1210ES Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
C 1210 ES/ESC
INDOOR RESIDENTIAL AND COMMERCIAL MODELS
Temperature Modulated with Electronic Ignition
Suitable for heating potable water and space heating
(Intended for variable flow applications)
C 1210 ES/ESC - Natural Gas
C 1210 ES/ESC - Liquefied Petroleum (LP) Gas
6 720 644 887 (2011/05) US
Warning: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas
supplier.
In the Commonwealth of Massachusetts this
product must be installed by a licensed plumber or
gas fitter.
Upon completion of the installation, these
instructions should be handed to the user of the
appliance for future reference.
What to do if you smell gas
Close gas valve. Open windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - C 1210 ES/ESC

C 1210 ES/ESCINDOOR RESIDENTIAL AND COMMERCIAL MODELSTemperature Modulated with Electronic IgnitionSuitable for heating potable water and space heatin

Page 2

6 720 644 88710Installation instructions3 Installation instructions3.1 Specialized toolsThe following specialized tools may be required for installati

Page 3 - 1 Warning

6 720 644 887Installation instructions113.3.1 Vent materialAll combustion air and vent pipe materials and fittings must comply with the following:For

Page 4

6 720 644 88712Installation instructions3.3.2 Vent specificationsEstablish vent clearances that comply with the ventmanufacturer's specif

Page 5 - 2 Appliance details

6 720 644 887Installation instructions13Calculation example for 3" venting:ExhaustCombustion airCalculation example for 4" venting:ExhaustCo

Page 6

6 720 644 88714Installation instructionsRequired direct vent terminal clearances (twin pipe / concentric penetration)Fig. 9* For clearances not specif

Page 7

6 720 644 887Installation instructions15Required other than direct vent terminal clearances (single pipe penetration)Fig. 10* For clearances not speci

Page 8

6 720 644 88716Installation instructions3.3.3 Vent configuration examplesBelow are approved examples of vertical and horizontal venting installations.

Page 9 - FLOOR (C) 12

6 720 644 887Installation instructions17Fig. 15 Horizontal venting system (single pipe pene-tration)*Warning: Single pipe penetration should be used i

Page 10 - 3 Installation instructions

6 720 644 88718Installation instructionsAppliance condensate drain installationThe appliance comes equipped with an internalcondensate drain and

Page 11 - DRAIN TEE

6 720 644 887Installation instructions19Backdraft reducerThe Heat Fab backdraft reducer (9301BFP) is the pre-ferred option for limiting backdraft (see

Page 12

6 720 644 8872IndexIndex1 Warning 32 Appliance details 52.1 Features 52.2 Specifications (Technical data) 52.3 Unpacking the tankless water heater

Page 13

6 720 644 88720Installation instructions3.3.7 Fan speed adjustment! IMPORTANT INFORMATION:Natural gas heaters with installation altitudesbelow 2

Page 14 - Table 16

6 720 644 887Installation instructions21NG LPG NG/LPGAltitude (above sea level)Vent terminalTotal equivalent vent length1)Minimum power fan speed (P2)

Page 15 - Table 17

6 720 644 88722Installation instructionsAdjusting minimum power fan speed (P2)To select fan speed:B Press ON/OFF button into OFF.B Press and hold

Page 16 - 6720608836-25.1Av

6 720 644 887Installation instructions23Attention residents of the Commonwealth of Massachusetts:In the Commonwealth of Massachusetts the followingreg

Page 17 - 6720608643-12.2V

6 720 644 88724Installation instructions3.4 Combustion air requirementsTwin pipeThe tankless water heater is designed as a sealedcombustion a

Page 18 - 6720608643-17.2V

6 720 644 887Installation instructions253.5 Proper location for installing your heaterCarefully select the location of the water heater. Forsa

Page 19

6 720 644 88726Installation instructionsFig. 27 Leveling wall mounting bracketFig. 28 Mounting the heater3.8Gas piping & connections Before conne

Page 20

6 720 644 887Installation instructions27Fig. 29 Gas connectionOnce connections are made, check for gas leaks at all joints. Apply some gas leak detect

Page 21

6 720 644 88728Installation instructionsFOR NATURAL GASMaximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and

Page 22

6 720 644 887Installation instructions293.9 Water connections B When facing the heater, the ¾" cold connection ison the bottom right and the hot

Page 23

6 720 644 887Warning31 WarningFor your safetyDo not store or use gasoline or other flammable,combustible or corrosive vapors and liquids

Page 24

6 720 644 88730Installation instructionsConnecting the pressure relief valve (PRV)The listed pressure relief valve must be installed at thetime of ins

Page 25 - 3.7 Mounting installation

6 720 644 887Installation instructions313.11 Filling the condensate trapThe condensate trap can be filled before or afterconnecting the vent p

Page 26 - 6720608836-10.1AL

6 720 644 88732Installation instructions3.12 Domestic hot water recirculationAlthough recirculation directly through the tanklesswater heater i

Page 27

6 720 644 887Installation instructions333.13 Space heating applicationsBosch tankless water heaters are approved for use incombination DHW and spac

Page 28 - FOR LP GAS

6 720 644 88734Installation instructionsFig. 42 Space heating diagram1 Hot water outlet2 Cold water inlet3 Pressure relief valve4 Gas supply5 Shut off

Page 29 - 3.10 Water quality

6 720 644 887Installation instructions353.14 Measuring gas pressureGas pressure must be measured upon installation.Connecting manometerB Shut off gas

Page 30

6 720 644 88736Electrical connections4 Electrical connections4.1 Electrical power supplyThe tankless water heater requires an electrical powersupply

Page 31

6 720 644 887Operation instructions375 Operation instructionsFig. 481 On/Off button2 Reset button3 Program button4 LCD display5 Up button6 Down button

Page 32 - 6720608836-12.1AL

6 720 644 88738Operation instructions5.2 For your safety read before operating your water heaterA. This appliance is equipped with electronic ignition

Page 33 - Pressure(FeetofHead)

6 720 644 887Operation instructions39Solar modeThe water heater will not ignite if inlet water temperatureexceeds the set temperature on the applia

Page 34 - Fig. 42 Space heating diagram

6 720 644 8874WarningFCC:This device complies with Part 15 of the FCC rules.Operation is subject to the following two conditions: (1)This dev

Page 35 - 3.14 Measuring gas pressure

6 720 644 88740Maintenance and service5.8 Program buttonFig. 63 “Program” key5.8.1 Memorizing selected temperatureB Press buttons or to select

Page 36 - 4 Electrical connections

6 720 644 887Maintenance and service41Inlet Water Filter• Verify the inlet filter screen is clean and undamaged.The inlet water filter is located betw

Page 37 - 5 Operation instructions

6 720 644 88742Maintenance and service13. Disconnect all lines and drain all solution from heatexchanger. Properly discard of solution.14. Position a

Page 38 - 5.4 Temperature selection

6 720 644 887Maintenance and service43P1 Operating Pressure: “ WCThe P1 minimum operating gas pressure is 3.5" WC for Natural Gas and 8" W

Page 39 - D A N G E R

6 720 644 88744Maintenance and serviceFinal ReadingsP1 CO2 Reading: % CO2P2 CO2 Reading: % CO2D. Returning to Service:1. Return slotted screw cove

Page 40 - 6 Maintenance and service

6 720 644 887Maintenance and service456.6 Program valuesThis section describes details on programming the appliance. For most applications the factory

Page 41 - 6.3 Mineral scale build-up

6 720 644 88746Maintenance and service6.7 Diagnostic menu1. Press ON/OFF button to turn off the appliance.2. Press and hold "Program"

Page 42 - 6.5 Adjusting CO

6 720 644 887Troubleshooting477 Troubleshooting7.1 IntroductionMany of the questions customers ask regardingoperation of this unit can be answer

Page 43

6 720 644 88748TroubleshootingContact your original installer or a local certified gastechnician to obtain this reading.7. Cold water is mixing in

Page 44 - 6720608836-04.1AL

6 720 644 887Troubleshooting49specifications in Section 3.4, page 24 CombustionAir Requirements.4. Cross contamination. Ensure that intake and exhaust

Page 45 - 6.6 Program values

6 720 644 887Appliance details52 Appliance details2.1 FeaturesResidential/commercial models• C 1210 ES residential model– maximum temperature 140° F•

Page 46 - 6.7 Diagnostic menu

6 720 644 88750Error codes8 Error codes8.1 Error code diagnosticsiTo remove error code from thedisplay, press the reset button.Display Cause Solu

Page 47 - 7 Troubleshooting

6 720 644 887Error codes51Primary fan rotation too low inoperation.1. Reset errors, disconnect power supply cord and check wireconnectio

Page 48 - 7.5 Low water flow/pressure

6 720 644 88752Error codesExhaust temperature sensor - theappliance will close the burner andlock if it gets over 194°F; (onlyapplied for co

Page 49

6 720 644 887Error codes53Ionization failure during operation. 1. Check gas type, Fig. 2, page 6.2. Check three wire connections to ignition gr

Page 50 - 8 Error codes

6 720 644 88754Electrical diagram9 Electrical diagramFig. 72 Electrical scheme1 Inlet water temperature sensor2 Outlet water temperature sensor3 Backf

Page 51

6 720 644 887Sensor resistance charts5510 Sensor resistance chartsFig. 73Fig. 74Outlet sensor characteristics3 23 74 24 752576 26 772778 28 79 29 710

Page 52

6 720 644 88756Sensor resistance chartsFig. 75Back Flow and Exhaust sensor characteristics3 23 74 24 75 25 76 26 77 27 78 28 79 29 710 210 711211712 2

Page 53

6 720 644 887Functional scheme5711 Functional schemeFig. 76 Functional scheme

Page 54 - 9 Electrical diagram

6 720 644 88758Interior components diagram and parts list12 Interior components diagram and parts list12.1 Interior componentsFig. 77 Components1 Exha

Page 55 - 10 Sensor resistance charts

6 720 644 887Interior components diagram and parts list59Fig. 78 Appliance overview6720608836-02.1AL

Page 56 - Sensor resistance charts

6 720 644 8876Appliance details• Minimum recommended water pressure: 30 PSI(2.07 bar)• Minimum well pressure 40 psi, see page 29.• Connections:–

Page 57 - 11 Functional scheme

6 720 644 88760Interior components diagram and parts list12.2 Components diagram12.2.1 Group 1Fig. 79 Components Diagram998512367910129141617111315154

Page 58 - 12.1 Interior components

6 720 644 887Interior components diagram and parts list6112.2.2 Group 2Fig. 80 Components Diagram10142815123025202122171628312681816131917272819132713

Page 59 - 6720608836-02.1AL

6 720 644 88762Interior components diagram and parts listItem Description Reference1 Heat exchanger 8 705 406 4192 Heat exchanger top gasket 8 704 701

Page 60 - 6720902973.AB JF

6 720 644 887Interior components diagram and parts list6312.2.3 Group 3Fig. 81 Components Diagram151413467821291113161756720902988.AA JF6Item Descript

Page 61 - Fig. 80 Components Diagram

6 720 644 88764Interior components diagram and parts list12.2.4 Group 4Fig. 82 Components Diagram9214134567811111213106720902990.AA JFItem Description

Page 62 - Table 31

6 720 644 887Interior components diagram and parts list6512.2.5 Group 5Fig. 83 Components Diagram91112131012344567891114151617126720902989.AA JF(optio

Page 63 - 6720902988.AA JF

6 720 644 88766Interior components diagram and parts list12.2.6 Group 6Fig. 84 Components Diagram376951041215131614126720608158-75.2V11Item Descriptio

Page 64 - 6720902990.AA JF

6 720 644 887Protecting the environment6713 Protecting the environment PackingThe packing box may be fully recycled as confirmed bythe recycling symbo

Page 65 - 6720902989.AA JF

6 720 644 88768LIFETIME LIMITED WARRANTY FOR BOSCH TANKLESS WATER HEATERS14 LIFETIME LIMITED WARRANTY FOR BOSCH TANKLESS WATER HEATERS14.1 Limited war

Page 66 - 6720608158-75.2V

6 720 644 887LIFETIME LIMITED WARRANTY FOR BOSCH TANKLESS WATER HEATERS69LIMITED WARRANTYOTHER THAN THE OBLIGATIONS OF BTCEXPRESSLY SET FORTH

Page 67

6 720 644 887Appliance details7To remove front coverB Loosen the two Phillips head screws located onbottom rear of cover (see Fig. 3).Fig. 3 Lo

Page 68 - 14 LIFETIME LIMITED WARRANTY

6 720 644 88770LIFETIME LIMITED WARRANTY FOR BOSCH TANKLESS WATER HEATERS14.2 Limited warranty for C 1210 ESC commercial modelMODELS COVEREDThis limi

Page 69

6 720 644 887LIFETIME LIMITED WARRANTY FOR BOSCH TANKLESS WATER HEATERS71INCLUDING, WITHOUT LIMIITATION, INJURY ORDAMAGE TO PERSONS OR PROPERT

Page 70

Bosch Termotecnologia SAEstrada de Cacia3800 - 533 Cacia - PORTUGALRecycled paper © 2011 Bosch Thermotechnology Corp., Londonderry, NHBOSCH THERMOTECH

Page 71

6 720 644 8878Appliance details2.4 General rules to follow for safe operationB 1. You must follow these instructions when youinstall your hea

Page 72 - 6720644887

6 720 644 887Appliance details92.5 Dimensions and minimum installation clearancesFig. 6 Dimensions1 On/Off button2 Reset button3 Program button4 Power

Comments to this Manuals