External
2
ventilation
High Low
Level Level
248 248
358 358
Room Sealed flue:*
Internal
1
ventilation
High Low
Model Level Level
32/50 495 495
50/70 715 715
External
2
ventilation
High Low
Level Level
248 495
358 715
Conventional flue:*
Internal
1
ventilation
High Low
Model Level Level
32/50 495 743
50/70 715 1073
This boiler is only suitable for installing
internally within a property at a suitable
location onto a fixed rigid surface of the same
size as the boiler and capable of supporting
the boiler weight.
The boiler must be installed on a flat level
surface to ensure condensate does not enter
the primary heat exchanger.
The boiler is not suitable for external
installation unless a suitable enclosure is
provided.
The boiler is not suitable for roof space
installations.
Open flue model (CF):
In order to ensure clean and efficient
combustion an adequate supply of air must
be delivered to the combustion chamber.
To provide sufficient air a suitable inlet must
be provided into the room or space in which
the boiler is situated.
An air brick or other form of continuous air
supply may have to be built into the installation
in order to ensure an adequate supply of air.
If the appliance is to be installed in a confined
space or compartment two air vents are
required, one at high level and one at low level.
The minimum free area of each vent is
shown opposite and depends whether the
air is taken from another room or from
outside the building.
Where the air is taken from another room that
room must contain an air inlet as described
above.
Room sealed balanced flue model (RS):
The appliance does not require a separate vent
for combustion air.
Installation in cupboards or compartments
require permanent vents for cooling purposes,
one at high level and one at low level, either
direct to outside air or to a room.
Both vents must pass to the same room or be
on the same wall to the outside air.
The minimum air vent free area is given in the
table opposite.
a: INSTALLATION CLEARANCES:
Diagram (a) shows the minimum space
recommended to install the boiler only.
b: SERVICE CLEARANCES:
Diagram (b) shows the minimum space
required to carry out an annual service.
c: MAINTENANCE & REPAIR CLEARANCES:
The appliance is suitable for an under worktop
installation providing that the worktop above the
boiler (min 10mm clearance) is removable for
maintenance and repair and the front of the
boiler is not enclosed.
* Due to changes to BS 5410 and modern
building design, these figures no longer
incorporate the adventitious ventilation allowance.
BOILER LOCATION & CLEARANCES
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR UTILITY 32/50 & 50/708 716
109 711B 07.2010
14
PRE -
INSTALLATION
BOILER LOCATION &
CLEARANCES
600mm
300mm
100mm
100mm
720mm
1415mm
13 12 m m
a: RECOMMENDED
INSTALLATION CLEARANCES
b: ANNUAL SERVICE CLEARANCES
600mm
300mm
10mm
10mm
720mm
1415mm
1312mm
c: MAINTENANCE & REPAIR
CLEARANCES
600mm
300mm
10mm
10mm
720mm
1415mm
1312mm
MINIMUM AIR VENT AREA (cm
2
) FOR APPLIANCES INSTALLED IN A COMPARTMENT:
1
Internal air to and from a space/room inside the building.
2
External air to and from directly outside the building.
32/50kW
CF minimum air inlet sizes*
248 358
50/70kW
Output
Size cm
2
8 716 109 711 b 07.10 14/7/10 09:59 Page 14