23
5. Make sure the water heater is vented properly. Check
for proper draft and ensure venting is in accordance
with manufacturer's specifications (see chapter 3.6).
6. The water heater has burners much like a furnace. It
is essential that they remain clean and are supplied with
adequate air for combustion. If the flames burn yellow or
orange, it is strongly recommended that the burners be
removed from the unit and cleaned. Once the burners
are removed, the fins in the top of the heat exchanger
can be accessed and should be brushed or vacuumed
clean. Instructions to remove burners are available at
www.boschhotwater.com.
7 Protecting the
environment
Packing
The packing box may be fully recycled as confirmed by
the recycling symbol .
Components
Many parts in the heater can be fully recycled in the end
of the product life. Contact your local authorities for
information about the disposal of recyclable products.
Saving water resources:
B Make sure you close all the taps after any use. Avoid
leaving the taps dripping. Repair any leaking tap.
B Set the water heat to the temperature you want. This
way you have the precise water temperature needed
(mixing cold water to regulate temperature will
increase the water temperature with consequent
waste of water).