Optical and top-load dispensers measure rinse-aid levels with optical sensors instead of reed
switches.
Service Tips
Service Tips
Optical Sensor Dispensers
Optical Sensor Dispensers
HINT: Optical
dispensers have
different connections
and can’t be
substituted for reed
switch dispensers.
Cable guide
Transmitter diode
Receiver
diode
Prism
When rinse-aid has run out, the optical
receiver senses a strong light beam.
Optical rinse-
aid sensor
NOTE: Top-load and standard
dispensers are NOT
interchangeable.
Standard dispenser
Top-load
dispenser
¾
¾
Transmitter diode
Receiver
diode
Prism
With rinse-aid present, the optical
receiver senses a diffused light beam.
Optical rinse-
aid sensor