Plena Universal Pre-amplifier | Installation and Operating Manual | en | 10
2.3 Setting emergency, insertion or cascade
The functionality of the insertion/cascade/emergency input is determined with jumper JP301 and the 'Ins/Casc'
switch at the back of the unit.
Input/output used for Jumper JP301 Switch
Insertion OFF INS
Cascade OFF CASC
Emergency ON CASC
Note
If you use the emergency option, the emergency volume can be set with VR301. This volume is not affected
by the master volume.