PTZ
Enable PTZ when a controllable camera is connected.
By default, PTZ is disabled for all inputs.
Contrast
Auto contrast - enabled to let the system automatically adjust the contrast for the video
input.
Contrast - can be set manually with the slider if Auto contrast is disabled.
Enable audio input
Enable Audio input when an audio source is connected.
The Level meter indicates the strength of the audio input signal.
Use the Gain slider to adjust the input sensitivity.
6.2.2 Channels 9 to 16 (or 17 to 24)
The tabs 9-16 or 17-24 across the top of the menu contain the settings for each of the IP
cameras.
Note:
An IP stream must only be connected to a single channel on a single Divar. There should be no
connection to any other device that could influence the settings of the IP device.
IP camera
If an IP connection has already been configured, the IP address, input type, and stream
number is displayed. If a connection has already been established, a video preview appears.
1. Click Setup to configure or change an IP camera connection.
IP address - enter the IP address of the IP camera.
Input - Choose Camera if the channel is connected to a camera or a single-channel
encoder. Choose Video line 1-4 if the channel is connected to a multi-channel
encoder.
Stream - enter the stream number.
Encoder profile - Displays the encoder profile of the IP device used by the Divar XF.
Username/Password - enter the username and password if applicable.
2. Press OK to confirm settings.
It can take a few seconds to establish a successful connection, after which a video preview
appears.
Input name
Enter a name for the selected input. The name can be up to 16 characters long.
Enable video input
This setting enables (default) or disables the video input.
PTZ
Enable PTZ when a controllable camera is connected.
By default, PTZ is disabled for all inputs.
Note:
Refer to the datasheet for a list of supported IP cameras and encoders.