2.4 Allegiant Error Messages
Error Name Description
Error 01 Invalid Camera Request The camera number entered from the keyboard does not exist. If
using the optional LTC 8059/00 Master Control Software or the LTC
8850/00 Graphical User Interface Software, ensure that the number
exists in the Camera Identification table. Download the table to be
sure.
Error 02 Invalid Monitor Request The monitor number entered from the keyboard does not exist.
Error 03 Remote Device Locked by User# The remote device requested cannot be controlled, because it is
locked by a user with equal or higher priority. Check with the other
users or request that a higher priority user unlock the remote
device.
Error 04 Monitor Locked by User# The monitor requested cannot be accessed, because it is locked by
a user with equal or higher priority. Check with the other users or
request that a higher priority user unlock the monitor.
Error 05 Remote Device Access Restricted Remote locked out by Remote Lock Out table.
Error 06 Monitor Access Restricted Monitor locked out by Monitor Lock Out table.
Error 10 Access Denied A function was requested for which the user priority is too low. Only
a Priority 2 user or a supervisor with Priority 1 may access this
function.
Error 11 Access Denied A function was requested for which the user priority is too low. Only
a supervisor with Priority 1 may access this function.
Error 15 Invalid User Function The function number requested from the keyboard is invalid. Refer
to the User Function table for a listing of valid user function
numbers.
Error 20 Acknowledge Denied The ACKNOWLEDGE button was pressed by a user without the
authority to acknowledge alarms.
Error 21 Incorrect Acknowledge In order to properly acknowledge an alarm event, the keyboard
must be switched to a monitor that is displaying the alarms.
Error 22 Acknowledge Disabled Alarms on this monitor cannot be acknowledged, because that
capability has been disabled by the system programmer.
Error 23 Camera not in Alarm The camera displayed on the monitor is not an alarm video; only
alarm-generated video can be acknowledged.
Error 24 Keyboard Not Enabled for
Acknowledge
This keyboard may not acknowledge alarm video on this monitor; it
has been disabled by the system programmer.
Error 25 Alarm Switcher Running Alarm video may only be acknowledged if the alarm switcher is not
running; press HOLD to stop the switcher.
Error 50 Sequence Not Available The user attempted to load a switcher sequence that does not exist.
This is a good way to determine, from the keyboard, which
sequence numbers are unused when desiring to add one. A request
was made to load an ABSOLUTE type sequence, without the
keyboard being on one of the monitors in that sequence. Because
inadvertent loading of monitors should be avoided, the user is
required to switch his keyboard to one of the monitors used by the
sequence. The PROGRAM mode may be used to review which
monitors are used in the sequence.
Error 52 Sequence Request A request was made to load a RELATIVE type sequence on a monitor
number that is too high; the monitors used by the sequence would
extend past the highest monitor. Try switching to a lower monitor
number before loading the sequence.