Language Settings for Windows Users Without Admin Rights. If a Windows user who does
not have admin rights on the RPS-LITE computer changes the default language setting
(for example, from English to Spanish), the change is not preserved when RPS-LITE is
closed and restarted. The setting reverts to the default language.
Changing the Computer’s Regional Settings Affects Date Displays. If you change your
RPS-LITE computer’s regional settings, some date displays might not appear correctly.
Invalid Messages. Some modems can cause RPS-LITE to generate an invalid RPS-LITE
passcode message as a result of a busy phone line. Calling an invalid control panel type
(for example, a D7024 account calling a D6412 control panel) does not always cause RPS-
LITE to generate an Invalid Panel Type error message. An Invalid RPS Passcode message
might appear instead.
RPS-LITE and Door Access Control Module (DACM) Software Compatibility. If you install
RPS-LITE and the DACM software on the same computer, the DACM software might not
start. Uninstall the DACM software, and then reinstall it.
Importing Accounts from Older Versions of RPS-LITE. Accounts imported from older
versions of RPS-LITE do not appear in the Panel List regardless of a successful import
message from RPS-LITE . This issue applies only to non-English versions of RPS-LITE
installed on compatible Microsoft Windows operating systems.
Extended Desktop Monitor Configuration. When using an Extended Desktop monitor
configuration, some of the dialog boxes and windows do not retain their last used
location. If you change from Extended Desktop to a Single monitor, some windows
attempt to open on the extended monitor.
Unattended Service known issues
Windows Users Without Admin Rights Cannot Turn Unattended Service On or Off.
Windows users who do not have admin rights on the RPS-LITE computer cannot turn
Unattended Service on or off.
UOM and Hayes 1200 Modem. Starting with RPS-LITE 5.13, the Hayes 1200 Modem is no
longer supported for Unattended Over Modem (UOM) operation.
UOM Init String for a GV3 Series or DS7400XiV4 Account. When using Unattended Over
Modem (UOM) with a GV3 Series or DS7400XiV4 control panel account, use the modem
init string for the DS7400XiV4 control panel.
Panel-Initiated Unattended Over Network (PI-UOM/UON). Changes trigger Unattended
Service to run unexpectedly. After a panel-initiated UOM/UON change, the Unattended
Service runs without alerting the RPS-LITE operator.
Intermittent Connection over IP and “U Comm Failure” Message. If there is an
intermittent connection over IP, the control panel and RPS-LITE can become
unsynchronized during a data Send. If this occurs, RPS-LITE logs a "U Comm Failure"
message in the Activity List. There is no visible indication (at the control panel or RPS-
LITE) other than the "U Comm Failure" message that indicates that the data send did not
finish properly.
Baud Rates for Panel-initiated Unattended Over Modem (PI-UOM). PI-UOM can only use
1200 baud. Baud rates of 300 and 2400 are currently not supported.
RPS printing known issues
Printing the Program Record Sheet (PRS). RPS-LITE might add extra blank pages when
printing the PRS to the .rtf file format. Some PRS reports printed in .pdf or .rtf format
might show unaligned data.
4.3
4.4
Remote Programming Software LITE
(RPS-LITE)
Version 5.19.4 known issues | en 9
Bosch Security Systems, Inc. Release Notes, version 5.19.4, Service Pack 1 2014.05 | 10 | F01U045286