Bosch LTC 5104 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
disabled) can be set to 1 to 63 seconds. Sequencing
through multiple alarms can be set to occur at a dwell
of 1 to 64 seconds.
Two modes of operation can be selected for the
LTC 5108 Series switchers. The two modes only affect
Monitor B; Monitor A continuously sequences
regardless of mode. In the Sequencing Mode, Monitor
B will show either an alarm call up of a camera, a
camera under a HOLD condition or normal sequencing
of cameras. In the Blanking Mode, Monitor B will show
either an alarm call-up of a camera, a camera under a
HOLD condition or a blank screen.
Simple front panel controls insure easy operation.
They include: a dwell button for a dwell adjust menu;
select buttons to select each channel; a skip/clear
button to skip channels or to clear alarms; an alarm
button to arm the monitor (Monitor B for the
LTC 5108 Series); and a run button to initiate auto-
sequencing or to select the next camera in the
sequence.
Supplied as compact desktop units, these switchers
can also be mounted with a rack-mount kit. A 609 mm
(24 in.) cable with 15-pin connectors is provided for
connecting a motion detector or remote alarm
closures to the switcher.
Certifications and Approvals
Electromagnetic
Compatibility (EMC)
Complies with FCC Part 15, ICES-003 and CE
regulations
Product Safety Complies with CE regulations, UL, CSA, EN
and IEC Standards
Region Certification
Installation/Configuration Notes
1
2
3
4
5
6
7
8
8
Typical Installation Using LTC 5108 Series Switcher
1 Motion Detector 5 Additional Cameras
2 Door Switch 6 Alarm Output Relay Closure
3 Smoke Detector 7 Video Recorder
4 To Terminated Auxiliary
Monitor or Terminated
Switcher
8 Cameras
Monitor A
Sequencing Mode
1. Normal sequencing of camera inputs
Blanking Mode
1. Normal sequencing of camera inputs
Monitor B
Sequencing Mode
1. Normal sequencing (same as Monitor A)
2. “HOLD” condition
3. “ALARM” condition
Blanking Mode
1. Blank screen
2. “HOLD” condition
3. “ALARM” condition
Technical Specifications
Electrical
Model No.
1
Rated Voltage Voltage
Range
Power at
Rated Voltage
LTC 5104/60 120 VAC,
50/60 Hz
105 to 130 4 W
LTC 5104/50 230 VAC,
50/60 Hz
198 to 264 4 W
LTC 5108/60 120 VAC,
50/60 Hz
105 to 130 4 W
LTC 5108/50 230 VAC,
50/60 Hz
198 to 264 4 W
1) Models shown are for English on-screen menus
model.
Switching Time Less than 1 µs
Dwell Time Each camera individually or globally set from
1 sec. to 64 sec.
Alarm Dwell Time 1 sec. to 64 sec.
Alarm Capture Time 1 sec. to 63 sec.
Video Gain Unity
Bandwidth (–3 dB point)
5 MHz minimum
2 | LTC 510x Series 4- and 8- position Premium Sequential Switchers