TECHNICAL BULLETIN
Intrusion GV2 Series, D8125INV Wireless Module
False Alarms on 24-Hour Points January 7, 2009
Issue Severity: Products Affected:
High: Act immediately
Medium: Bosch Security Systems, Inc.
strongly recommends you take the action(s)
described below.
Low: Advisory
GV2 Series Control Panels
D8125INV Wireless Interface Module
1.0 Issue
GV2 Series control panels using the D8125INV Wireless Interface Module might indicate false alarms for
24-hour wireless points.
2.0 Resolution
This problem occurs if the Debounce setting for 24-hour wireless points is set to 1.
To correct the problem, use RPS or the D5200 Programmer and navigate to POINTS (RADXPNTS) Point
Assignments Debounce, then make sure that all 24-hour wireless points have Debounce set to 2 or greater.
Bosch Security Systems, Inc. recommends leaving the Debounce parameter at the default value of 2.