Bosch D720W User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 7
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
ISW‑EN1235SF Fixed‑location Transmitter (Double‑button)
ISW‑EN1242 Smoke Detector‑Transmitter
ISW‑EN1247 Glassbreak Sensor‑Transmitter
ISW‑EN1249 Billtrap Transmitter
ISW‑EN1260 PIR Motion Sensor Transmitter (Commercial and High‑end
Domestic Applications)
ISW‑EN1261HT PIR Motion Sensor Transmitter (High‑traffic Areas)
ISW‑EN1262 PIR Motion Sensor Transmitter (Residential and
Low‑traffic Commercial Applications)
ISW‑EN1265 PIR Motion Sensor Transmitter (Ceiling‑mount
Applications)
Parts included
The D7412GV3 includes the following parts:
Quant. Component
1 D7412GV3 Board
1 Mounting Skirt
1 Faceplate with D7412GV3 Label
1 Literature pack
Installation Instructions
Owners Manual
Release Notes
1 Literature CD containing all product literature
The available kits come with the parts indicated in the
following table:
Kits
Components -A -B -C -D
D7412GV3 Board 1 1 1 1
D101F Lock and Key Set 1 1
D122 Dual Battery Harness 1
D161 Dual Modular Phone Cord 2
D928 dual Phone Line Switcher 1
D1640 Transformer 1 1 1 1
D6103 Enclosure 1
D8103 Enclosure 1
D8108A Attack‑resistant Enclosure 1
D8109 Firwe Enclosure 1
Technical specifications
Communications
SDI Bus A (+): 9 VDC
4572 m (15,000 ft)
SDI Bus B (-): 9 VDC
4572 m (15,000 ft)
Telephone
Connection:
One telephone line
D928 Dual Phone Line module required for
two telephone lines
Electrical
Current Draw (Maximum): 300 mA
Output (Alarm): 2 A at 12 VDC
Output (Auxiliary, Continuous
Power, and Switched Auxiliary
combined):
1.4 A at 12 VDC nominal
Voltage (Operating): 12 VDC nominal
Voltage (AC): 16.5 VAC 40 VA plug‑in
transformer (D1640)
Environmental
Relative Humidity: 5% to 93% at +30°C (+86°F),
non‑condensing
Temperature (Operating): 0°C to +50°C (+32°F to +122°F)
Number of…
Areas: 8
Card Readers (Doors): 2
Credentials (Tokens): 396
Custom Functions: 4
Events: Store up to 1,000
Parallel Printers: 1
Passcode Users: 99, plus 1 service passcode
Points: 75 (8 on‑board, up to 67
off‑board)
Programmable Relay Outputs: 67
RF Points: 67
SKEDs: 40
Trademarks
Trademark names are used throughout this document.
In most cases, these designations are claimed as
trademarks or registered trademarks in one or more
countries by their respective owners. Rather than
placing a trademark symbol in every occurrence of a
trademark name, Bosch Security Systems, Inc. uses
the names only in an editorial fashion and to the
benefit of the trademark owner with no intention of
infringing the trademark.
5
| D7412GV3 Control Panel
Page view 4
1 2 3 4 5 6 7

Comments to this Manuals

No comments