D7212G Operation and Installation Guide
Page 26 © 2003 Bosch Security Systems4998138544C
D7212G
4.2.2 Installing the Battery
Place the battery upright in the base of the enclosure. Locate the red and black leads supplied in the literature pack. Connect
the black battery lead to Terminal 4, and then to the negative (-) side of the battery. Connect the red battery lead to Terminal
5, and then to the positive (+) side of the battery.
WARNING
High Current Arcs Possible : The positive (red) battery lead and Terminal 5 can create high current arcs if shorted
to other terminals or the enclosure. Use caution when working with the positive lead and Terminal 5. Always
disconnect the positive (red) lead from the battery before removing it from Terminal 5.
CAUTION
The Battery Terminals and Wires are NOT Power Limited. A ¼ in. (6.4 mm) spacing must be maintained between
the battery terminals, battery wiring and all other wiring. Battery wiring may not share the same conduit, conduit
fittings or conduit knock-outs with other wiring. See Figure 5.
¼ in. (6.4 mm) minimum
spacing between battery wires
and other wires in any direction
Option
Wires
Output or
Zone Wires
Only required if
external batteries
are used
EARTH GROUND
COMMON
BATTERY NEGATI
Maximum Charging
Current 1.4 Amps.
BATTERY POSITIVE ONLY
RELAY A
RELAY B
RELAY C
+ AUX
1
2
3
4
5
6
7
8
9
10
D
PROGRAMMABLE
ALARM OUTPUTS
Ter minals
Requires Optional
D136 Relay
In ALT ALARM
& SW AUX
&
78
GROUND FAULT DETECT
Enabled
Disabled
PHONE
LED
RED
ON WHEN
COMMUNICATING
OFF WHEN IDLE
LOOP START
GND START
GROUND START
1211 13
Point 1
Point 2
GROUND START
Requires
Relay # D136 in
Ground
Start Socket
Battery Wires
To Batteries
To ensure proper
spacing secure
wires using
Tie-Wraps or
similar devices.
Battery terminals and
wires are not power
limited
Standby Battery
Figure 5: Non Power Limited Wiring
4.2.3 Replacing the Battery
Bosch Security Systems recommends battery replacement every 3 to 5 years under normal use. Exceeding the maximum
output ratings, or installing the transformer in an outlet that is routinely switched off, causes heavy discharges. Routine
heavy discharges can lead to premature battery failure. Record the date of installation directly on the battery.
D8132 boosts battery backup: Adding a D8132 Battery Charger Module supports additional batteries of up to 27 Ah capacity
if required.
The D8132 Battery Charger Module can be used to connect two additional batteries for a total of four. The panel plus any
connected D8132 Modules and AUX power supplies must be on the same AC circuit so they will discharge evenly if AC power
fails. The number of D8132 Modules is determined by the number of available outlets on the same circuit. See Section 4.1
Current Rating Chart for Standby Battery Calculations in the D7212G Approved Applications Compliance Guide (P/N:
4998138560) for battery standby time calculations.
Note: In applications where the supervision of two batteries is required by the AHJ, a D113 Battery Supervision Module
must be used.