Bosch D9412GV2 User Manual

Browse online or download User Manual for Security access control systems Bosch D9412GV2. D9412GV2 Control Panel - Bosch Security Systems

  • Download
  • Add to my manuals
  • Print
  • Page
    / 7
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Intrusion Alarm Systems | D9412GV2 Control Panel
D9412GV2 Control Panel
www.boschsecurity.com
u Fully integrated intrusion, fire, and access control
allows users to interface with one system instead of
three
u Conettix IP‑based communication option provides
high‑speed, secure alarm transport and control
u Eight programmable areas with perimeter and
interior partitioning
u 246 points with flexible configuration options to
meet multiple installation requirements
u Your choice of vacuum fluorescent or ATM style user
interface keypads
The D9412GV2 Control Panel provides an integrated
solution for intrusion, access control, and fire alarm
system applications. The control panel includes a
communicator that sends events to selected public
switched telephone network (PSTN) or IP network
destinations through four programmable route groups.
The control panel provides up to 246 individually
identified points. Each point:
Accommodates normally‑open (NO) and
normally‑closed (NC) devices with end‑of‑line (EOL)
resistor supervision
Is programmable for fire, fire supervisory, or intrusion
applications.
With the D9412GV2 you can:
Monitor alarm points for intruder or fire alarms while
operating user keypads and other outputs
Program all system functions on‑site through a D5200
Programmer or remotely through Remote
Programming Software (RPS).
Add up to eight doors of access control using the
optional D9210BLC Access Control Interface Module.
Functions
Programmable Outputs
2 A alarm power at 12 VDC
1.4 A auxiliary power at 12 VDC
Four alarm‑output patterns
Programmable bell test
Programmable bell shut‑off timer
System Response
31 custom point indexes, including fire supervisory
Selectable point response time
Cross point capability
Fire alarm verification
Fire inspector’s local test
Watch mode
Scheduled events (skeds) arm, disarm, bypass and
unbypass points, control relays, control authority
levels, and control door access
User Interface
Supervision of up to eight keypads (up to 32
unsupervised keypads can be used)
Custom keypad text
Full function command menu including custom
functions
Authority by area and 16‑character name for each
user
14 custom authority levels control user’s authority to
change, add, or delete passcodes or access control
credentials; to disarm or bypass points; and to start
system tests
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - D9412GV2 Control Panel

Intrusion Alarm Systems | D9412GV2 Control PanelD9412GV2 Control Panel www.boschsecurity.com u Fully integrated intrusion, fire, and acce

Page 2

NoticeUse at least one keypad in each system.Area ConfigurationsArea programming offers a wide selection of differentsystem configurations. Each area

Page 3

Scheduled Events (Skeds)The internal clock and calendar start individuallyscheduled events (skeds). Skeds perform functionssuch as arm or disarm, rela

Page 4 - 4

Magnetic Contacts Bosch magnetic contacts include recessed,terminal connection, miniature, overheaddoor,and surface mount.Modules C900V2 Dialer Captur

Page 5

ISW‑EN1233D Necklace Pendant Transmitter(Double‑button) ISW‑EN1233S Necklace Pendant Transmitter(Single‑button) ISW‑EN1235D Beltclip Pendant Trans

Page 6

D9412GV2 Kit Ordering Information KitsComponents D9412GV2-A D9412GV2-CA-A D9412GV2-B D9412GV2-C D9412GV2-CA-CD9412GV2 Board1 11D9412GV2 Board for C

Page 7

D8103 EnclosureGrey steel enclosure measuring 41 cm x 41 cm x 9 cm(16 in. x 16 in. x 3.5 in.).Order number D8103D8108A Attack Resistant EnclosureGrey

Comments to this Manuals