Bosch HSN 232 B Specifications

Browse online or download Specifications for Telephones Bosch HSN 232 B. Bosch HSN 232 B Specifications [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
74-06176-000-B 9/95 © 1995 Radionics
R A D I O N I C S
D5200 Programmer
Operation Manual
A-5200-030-000
Page view 0
1 2 3 4 5 6 ... 50 51

Summary of Contents

Page 1 - Operation Manual

74-06176-000-B 9/95 © 1995 RadionicsR A D I O N I C SD5200 ProgrammerOperation ManualA-5200-030-000

Page 2 - Table of Contents

D5200 Programmer Operation ManualPage 9© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-80Function KeysSix function keys simplify the use of the p

Page 3 - List of Figures

D5200 Programmer Operation ManualPage 10© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-1003. Disk OperationsThe D5200 contains memory which hold

Page 4 - 1. Introduction

D5200 Programmer Operation ManualPage 11© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-100Changing the Current DiskAt the Current Disk prompt in

Page 5 - Connectors

D5200 Programmer Operation ManualPage 12© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-1204. Product Handlers MenuWhen the D5200 ON button is pr

Page 6 - Specifications

D5200 Programmer Operation ManualPage 13© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-120SECURITYThe SECURITY menu includes items for programm

Page 7 - 1-800-538-5807

D5200 Programmer Operation ManualPage 14© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-1405. Programming RecordsThe example in this chapter show

Page 8 - 2. Overview of Operation

D5200 Programmer Operation ManualPage 15© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-140PRODUCT HANDLERLEVEL20714112611263671128112DISKSTATSEC

Page 9 - Figure 3: PROGRAMMER LEVELS

D5200 Programmer Operation ManualPage 16© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-160The handler title is always shown in the top line of t

Page 10 - Helpful Tones

D5200 Programmer Operation ManualPage 17© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-160Creating a New RecordScroll through the 7112 handler m

Page 11 - 3. Disk Operations

D5200 Programmer Operation ManualPage 18© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-180Entering a CategoryScroll through the Panel Wide Param

Page 12 - Formatting a Disk

D5200 Programmer Operation ManualPage 1© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-00NoticeThe material and instructions in this manual have

Page 13 - Rev [# # . # #]

D5200 Programmer Operation ManualPage 19© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-180Programmer Tips – Making CorrectionsThe following keys

Page 14 - 5200 OFF

D5200 Programmer Operation ManualPage 20© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-200Indexed Group Entry ExampleExit the Phone category usi

Page 15 - 5. Programming Records

D5200 Programmer Operation ManualPage 21© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-200Programmer Tip – Saving and Replacing RecordsWhenever

Page 16

D5200 Programmer Operation ManualPage 22© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-220REPLACING the Record: To save the edited record under

Page 17 - Page 16

D5200 Programmer Operation ManualPage 23© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-220Copying a RecordTo copy a record (save it under a diff

Page 18 - PASSCODE WORKSHEET

D5200 Programmer Operation ManualPage 24© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-240Deleting a RecordFollow the steps below to delete a re

Page 19 - Modem Format Yes

D5200 Programmer Operation ManualPage 25© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-240Making Program Items Invisible (VISMODE)Program items,

Page 20 - Exiting a Category

D5200 Programmer Operation ManualPage 26© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-260Locking RecordsIndividual records can be locked, preve

Page 21 - ... changes these prompts

A-5200-030-260© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 276. Sending (Loading) RecordsA record can be sent (loa

Page 22 - Editing a Record

D5200 Programmer Operation ManualPage 28© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-280J2PROGRAMMERTEST CONNECTORM AromatDS2E-M-DC12VM Ar

Page 23 - NAME: RESIDENTIAL4

D5200 Programmer Operation ManualPage 2© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-20List of FiguresFigure Page1. D5200 Programmer...

Page 24 - TO: RESIDENTIAL7

A-5200-030-280© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 297. Receiving (Copying) RecordsA record can be copied f

Page 25 - NAME: TESTRECORD

D5200 Programmer Operation ManualPage 30© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-3008. PasswordsAccess to several functions of the D5200 c

Page 26 - V

A-5200-030-300© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 31U#Update Handler: Enter Y to give U#Password the autho

Page 27 - LOCK RECORD: Yes

D5200 Programmer Operation ManualPage 32© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-3209. LockCodesThe DataLock system uses lockcodes to lock

Page 28 - 6. Sending (Loading) Records

A-5200-030-320© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 3310. Updating HandlersThe update feature of the D5200 c

Page 29 - 74-06176-000-B 9/95

D5200 Programmer Operation ManualPage 34© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-340Disk to Disk UpdatesHandlers and locked records can be

Page 30 - Connecting the Programmer

A-5200-030-340© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 35Updating using the Radionics Update System via the Pho

Page 31 - 8. Passwords

D5200 Programmer Operation ManualPage 36© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-3605. Mode prompt entry:To transfer a handler to internal

Page 32 - Page 31

A-5200-030-360© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 37Updating via RS-232Using the serial interface, handler

Page 33 - 9. LockCodes

D5200 Programmer Operation ManualPage 38© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-3803. Press the white ENTER key. The message WAITING for

Page 34 - 10. Updating Handlers

D5200 Programmer Operation ManualPage 3© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-201. IntroductionThe D5200 Programmer is a state of the ar

Page 35 - Mode: A -> B

A-5200-030-380© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 39Figure 29: TELCO UPDATE CONFIGURATIONUpdating via the

Page 36 - RADIONICS

D5200 Programmer Operation ManualPage 40© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-4003.Wait until the phone rings, and then press the whit

Page 37 - Block:xxx:

A-5200-030-400© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 4111. Deleting HandlersTo delete a handler from a disk o

Page 38 - B → RS232

D5200 Programmer Operation ManualPage 42© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-4205. To return to the Product Handlers level, press the

Page 39 - SENDING 7112

A-5200-030-420© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 4313. Help ScreensHelp screens can be accessed from almo

Page 40 - B → TELCO

D5200 Programmer Operation ManualPage 44© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-44014. Inside the ProgrammerThe inside of the programmer

Page 41 - TELCO → B

A-5200-030-440© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 45of both hands in the flared handle of the case. Pull t

Page 42 - 11. Deleting Handlers

D5200 Programmer Operation ManualPage 46© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-460Adjusting the LCD Display ContrastWith a small screwdr

Page 43 - 12. Programmer Time Out

A-5200-030-460© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 47HANDLER NOT FOUND This message is displayed if the han

Page 44 - 13. Help Screens

D5200 Programmer Operation ManualPage 48© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-480D5200 Security UtilityPasswords and Lockcodes Record S

Page 45 - 14. Inside the Programmer

D5200 Programmer Operation ManualPage 4© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-40ON HELPCANCELRECV(COPY)SEND(LOAD)CLEAREXITGROUPENTERGROU

Page 46 - Changing the Batteries

A-5200-030-480© 1991-1995 Radionics74-06176-000-B 9/95D5200 Programmer Operation ManualPage 49

Page 47 - 15. Troubleshooting Guide

ProductHandler ANumber ofrecords saved(or expectedto be saved) CMax. No. ofRecords forO/S Space DSpace Requiredfor Records(A/C)

Page 48 - Disk Operations

D5200 Programmer Operation ManualPage 5© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-40Power SourcesThree sources are available to provide powe

Page 49 - D5200 Security Utility

D5200 Programmer Operation ManualPage 6© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-60 Removable RAM CardCall Radionics Customer ServiceFor Re

Page 50 - A-5200-030-480

D5200 Programmer Operation ManualPage 7© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-602. Overview of OperationThe D5200 is designed to store r

Page 51 - ↑ round up to

D5200 Programmer Operation ManualPage 8© 1991-1995 Radionics74-06176-000-B 9/95A-5200-030-80PRODUCTHANDLERSDISKSTAT2071411261126368112SECURITYUPDATE

Comments to this Manuals

No comments