Bosch SHE3AR76UC Installation Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
5
The customer has the responsibility of ensuring that the dishwasher
electrical installation is in compliance with all national and local electrical
codes and ordinances. The dishwasher is designed for an electrical supply
of 120 V, 60 Hz, AC, connected to a dishwasher-dedicated, properly
grounded electrical circuit with a fuse or breaker rated for 15 amps.
Electrical supply conductors shall be a minimum #14 AWG copper only
wire rated at 75°C (167°F) or higher.
This appliance must be connected to a grounded metal, permanent wiring
system, or an equipment-grounding conductor must be run with the circuit
conductors and connected to the equipment-grounding terminal or lead on
the appliance. Do not use extension cords.
Avoiding Plumbing/Scalding Hazards
Do not perform any work on a charged hot water line. Serious injury could
result. Only a qualied plumber should perform plumbing work. Do not
attempt any work on the dishwasher hot water supply plumbing until you
are certain the hot water supply is shut o.
Do not over tighten the 90° elbow. Doing so may damage the water inlet
valve and cause a water leak.
Check local plumbing codes for approved plumbing procedures and ac-
cessories. All plumbing should be done in accordance with national and
local codes.
These instructions depict an installation method for stainless steel braided
hose or PEX hot water supply lines. If using copper tubing or other material
for water supply, defer to a licensed plumber for proper installation.
Inspect the Dishwasher
After unpacking the dishwasher and prior to installation, thoroughly inspect
the dishwasher for possible freight or cosmetic damage. Report any
damage immediately. Cosmetic defects must be reported within 30 days
of installation.
NOTE: Do not discard any bags or items that come with the original package
until after the entire installation has been completed.