Page 1 - VIDEOJET multi 4000

VIDEOJET multi 4000VJM-4016 en Installation Manual

Page 2

SummaryThe VIDEOJET multi 4000 encoder provides the following main functions:– Video, audio, and data transmission over IP data networks– Dual Streami

Page 3 - Table of contents

Connections, controls and displaysFront view1 Factory reset buttonto restore factory default settings2 LED ACTIVITYflashes during data transmission3 L

Page 4

Rear view1 VIDEO IN 1 to VIDEO IN 16 video inputsBNC socket for connecting the video source2 ETH RJ45 socketfor connecting to an Ethernet LAN (local n

Page 5 - Installation and operation

InstallationPreparationsThe VIDEOJET multi 4000 encoder is designed for installation in a switch cabinet. Mountingthe unit in a 19-inch rack using the

Page 6 - Maintenance and repair

14 en | Installation VIDEOJET multi 40002014.02 | V1 | F.01U.298.750 Installation Manual Bosch Sicherheitssysteme GmbH

Page 7 - Short information

ConnectionConnecting camerasYou can connect a maximum of 16 video sources to the VIDEOJET multi 4000 encoder. Anycameras and other video sources that

Page 8 - System overview

Establishing the network connectionYou can connect the unit to a 10/100/1000 Base-T network using a standard UTP category 5cable with RJ45 plugs.4 Con

Page 9 - System overview

Connecting audioThe unit has two audio ports for audio line signals.The audio signals are transmitted two-way and in sync with the video signals. The

Page 10

Connecting alarm inputs and relay outputNotice!For correct connection of alarm inputs and relay outputs, observe the labelling on the unit.Alarm input

Page 11 - Front view

2. Connect the terminal block to the socket on the unit observing the labeling.See also– Terminal block, page 25Creating a serial connectionNotice!For

Page 13 - Installation

Power on/power offDepending on the ordered product package, the unit is delivered together with a power cord.Notice!Use only a suitable power cord. Wh

Page 14

ConfigurationSetupBefore you can operate the unit within your network, it must have a valid IP address for yournetwork and a compatible subnet mask.No

Page 15 - Connection

Additional parametersYou can check and set additional parameters with the assistance of the Configuration Managerapplication in Video Client. You can

Page 16

TroubleshootingContactIf you are unable to resolve a malfunction, please contact your supplier or systems integrator,or go directly to Bosch Security

Page 17 - Connecting audio

Malfunction Possible causes Recommended solutionControl of cameras orother units is notpossible.The cable connection betweenthe serial interface and t

Page 18

STATUS LEDLights up: Startup in progress.Flashes: The unit is faulty, for example following failed firmwareupload.CONNECT LEDLights up: The unit is sw

Page 19 - Creating a serial connection

The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. Themode used depends on the current configuration.The pin assignme

Page 20 - Power on/power off

MaintenanceUpdatesFirmware updates are carried out via our Video Client software or other management systemsin use. Please refer to the relevant docum

Page 21 - Configuration

DecommissioningTransferVIDEOJET multi 4000 should only be passed on together with this installation manual.DisposalYour Bosch product is designed and

Page 22

Technical dataElectricalInput voltage 100 to 240 V AC, 47 to 63 HzInput current 0.32 to 0.15 APower consumption 23 W maxConnectors IEC 320 C14Mechanic

Page 23 - Troubleshooting

Table of contents1Safety 51.1 Electric shock hazard 51.2 Installation and operation 51.3 Maintenance and repair 62Short information 72.1 About this ma

Page 24

Total delay 260 ms typicalDual Streaming Full performance and full frame rate on both streams for everyvideo input channelFrame rate 1 to 25/30 ips (P

Page 25

IndexAAlarm, 12Alarm input, 18Audio connections, 12, 17CCameras, 15Closing contact, 18Conventions, 7DDanger, 5Data interface, 19DefaultIP address, 21D

Page 28 - Decommissioning

Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanywww.boschsecurity.com© Bosch Sicherheitssysteme GmbH, 2014

Page 29 - Technical data

10Technical data 2910.1 Electrical 2910.2 Mechanical 2910.3 Environmental conditions 2910.4 Standards 294 en | Table of Contents VIDEOJET multi 400020

Page 30

SafetyElectric shock hazard– Never attempt to connect the unit to any power network other than the type for which itis intended.– Connect the unit to

Page 31

– When making connections, use only the cables supplied or use appropriate cablesimmune to electromagnetic interference.– Position and run all cables

Page 32

Short informationAbout this manualThis manual is intended for persons responsible for the installation and operation of theVIDEOJET multi 4000 encoder

Page 33

System overviewParts included– 1 VIDEOJET multi 4000 video encoder– 1 accessory bag– 1 Installation Manual– optional: 1 power cord (depending on the o

Page 34

Audio encodingThe VIDEOJET multi 4000 encoder uses the G.711, AAC, and L16 audio compressionstandards. G.711 is the default setting for live transmiss