| 207
Optical network limits
Number of nodes
-
The maximum number of nodes that you can
connect to the optical network of the central
control unit is 61.
Number of WAPs
-
The maximum number of DCN‑WAP Wireless
Access Points in the optical network is 1.
Cables
-
The maximum length of the standard network
cable LBB4416/xx (Plastic Optical Fiber) cable is
50 m.
-
If longer cables are required, the PRS‑FINNA can
be used to convert from plastic to glass and vice
versa. The maximum cable length of Glass Optical
Fiber is dependent on the used Plastic Optical
Fiber plus the equivalent cable length per used
device.
-
The minimum bend radius of a 90 degree bend in a
POF cable is 25 mm.
-
The minimum coiling radius of a POF cable is 100
mm.
Power capacity
-
It is important that the devices in the optical
network do not use more total power than you
supply to the devices. Each device uses power and
most devices do not have an independent power
supply.
Note Refer to the DCN installation and operation
manual and use the DCN calculation tool for
DCN network limits in general.