MODEL GWH 2700 ES NG and GWH 2700 ES LP -
INDOOR MODEL
Temperature Modulated with Electronic Ignition
Suitable for heating potable water only
Not approved for space heating purposes
(Intended for variable flow applications)
GWH 2700 ES NG - Natural Gas
GWH 2700 ES LP - Liquefied Petroleum (LP) Gas
6 720 608 542 (2009/03) US
Warning: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any other
appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas
supplier.
In the Commonwealth of Massachusetts this
product must be installed by a licensed plumber or
gas fitter.
Upon completion of the installation, these
instructions should be handed to the user of the
appliance for future reference.
What to do if you smell gas
Close gas valve. Open windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
If you cannot reach your gas supplier, call the fire
department.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Page view 0
1 2 3 4 5 6 ... 59 60

Summary of Contents

Page 1 - INDOOR MODEL

MODEL GWH 2700 ES NG and GWH 2700 ES LP - INDOOR MODELTemperature Modulated with Electronic IgnitionSuitable for heating potable water onlyNot approve

Page 2

6 720 608 54210Installation instructionsHorizontal venting systems only:An optional stainless concentric vent/air intake termina-tion can be used to p

Page 3 - 1 Warning

6 720 608 542Installation instructions11Condensate drain requirementsAn external condensate drain (not supplied with theheater) must be inst

Page 4 - D A N G E R

6 720 608 54212Installation instructionsRequired direct vent terminal clearances (twin pipe / concentric penetration)Fig. 11* For clearances not speci

Page 5

6 720 608 542Installation instructions13Required other than direct vent terminal clearances (single pipe penetration)Fig. 12* For clearances not speci

Page 6 - 2.3 Unpacking the heater

6 720 608 54214Installation instructions3.3.3 Venting configuration examplesBelow are approved examples of horizontalventing installations.Fig. 1

Page 7

6 720 608 542Installation instructions15Fig. 17 Vertical venting installation (twin pipe penetra-tion)Fig. 18 Vertical venting installation - Masonry

Page 8 - 6 "

6 720 608 54216Installation instructions3.3.5 Condensate drain installationNote: Do not install condensate drain in areas where it may freeze.1. Insta

Page 9 - 3 Installation instructions

6 720 608 542Installation instructions173.3.6 Fan speed adjustmentIMPORTANT! Installation adjustment:After installing the water heater, the fan speed

Page 10 - 12"

6 720 608 54218Installation instructionsAdjusting minimum power fan speed (P2)To select fan speed:B Press ON/OFF button into OFF.B Press and hold &

Page 11 - 6 720 608 542

6 720 608 542Installation instructions19Attention residents of the Commonwealth of Massachusetts:In the Commonwealth of Massachusetts the followingreg

Page 12 - Installation instructions

6 720 608 5422IndexIndex1 Warning 32 Appliance details 42.1 Features 42.2 Specifications (Technical data) 52.3 Unpacking the heater 62.4 General

Page 13

6 720 608 54220Installation instructions3.4 Combustion air requirementsTwin pipe and Concentric pipeThe water heater is designed as a sealed combustio

Page 14

6 720 608 542Installation instructions213.5 Proper location for installing your heaterCarefully select the location of the water heater. Foryo

Page 15 - 6720608158-14.2AL

6 720 608 54222Installation instructionsFig. 25 Leveling the mounting bracket on the studsFig. 26 Mounting the heater3.8Gas piping & connections B

Page 16 - 3'MIN

6 720 608 542Installation instructions23Once connections are made, check for gas leaks at alljoints. Apply some gas leak detection solution to all gas

Page 17

6 720 608 54224Installation instructionsFOR NATURAL GASMaximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and

Page 18

6 720 608 542Installation instructions253.9 Water connections B When facing the heater, the ¾” cold connection is on the bottom right and the hot conn

Page 19

6 720 608 54226Installation instructionsConnecting the pressure relief valve (PRV)A listed pressure relief valve supplied with the heatermust be in

Page 20

6 720 608 542Installation instructions273.12 Measuring gas pressureConfirm gas pressure upon installation.Connecting manometerB Shut off gas supply at

Page 21 - 3.7 Mounting installation

6 720 608 54228Electrical connections4 Electrical connections4.1 Electrical power supplyThe water heater requires an electrical power supplyfro

Page 22 - Gas piping & connections

6 720 608 542Operation instructions295 Operation instructionsFig. 381 On/Off button2 Reset button3 Program Key4 LCD display5 Up button6 Down button7 L

Page 23

6 720 608 542Warning31 WarningFor your safetyDo not store or use gasoline or other flammable,combustible or corrosive vapors and liquids

Page 24

6 720 608 54230Operation instructions5.2 For your safety read before operating your water heaterA. This appliance is equipped with electronic ignition

Page 25 - 3.10 Water quality

6 720 608 542Operation instructions315.5 Use of optional remote control accessory (part no. TSTAT2)Fig. 47 Remote controlThe wireless remote contro

Page 26 - 6720608158-77.1AL

6 720 608 54232Maintenance and service6 Maintenance and serviceThe unit should be checked once a year by a gastechnician. If repairs are nee

Page 27

6 720 608 542Maintenance and service33space which is likely to experience freezingtemperatures, all water must be drained from the heater.If pre

Page 28 - 4 Electrical connections

6 720 608 54234Maintenance and serviceStatic Gas Pressure: “ WCP1 Operating Pressure: “ WCThe P1 minimum operating gas pressure is 3.5" WC for

Page 29 - 5 Operation instructions

6 720 608 542Maintenance and service35Final ReadingsP2 CO2 Reading: % CO2P1 CO2 Reading: % CO2Fig. 57 Adjusting P1 CO2 levelFig. 58 Adjusting P2 CO2

Page 30 - 5.4 Temperature selection

6 720 608 54236Maintenance and service6.5 Program valuesThis section describes details on programming theappliance. For most applications th

Page 31

6 720 608 542Maintenance and service376.6 Control board diagnostics1. Turn on/off switch on water heater to off (O) position.2. Press and hold the

Page 32 - 6 Maintenance and service

6 720 608 54238Troubleshooting7 Troubleshooting7.1 IntroductionMany of the questions customers ask regardingoperation of this unit can be answer

Page 33 - (carbon dioxide)

6 720 608 542Troubleshooting39heater. Then open all of the hot water taps served bythe heater. Wait 10 minutes and check all taps forwater flow. The

Page 34

6 720 608 5424Appliance detailsFCC:This device complies with Part 15 of the FCC rules.Operation is subject to the following two conditions: (

Page 35 - 6720608158-38.1AL

6 720 608 54240Troubleshooting5. Lack of adequate gas pressure. Inadequate gaspressure will cause the fuel-to-air mixture (CO2) to beout of adju

Page 36 - 6.5 Program values

6 720 608 542Problem solving418 Problem solving8.1 Error code diagnosticsiTo remove error code from the display, press the reset button.Display Cause

Page 37

6 720 608 54242Problem solving (Flashing) Outlet temperature sensor notsensing expected outputtemperature.1. Check that the sensor is firmly atta

Page 38 - 7 Troubleshooting

6 720 608 542Problem solving43Over-temperature detected byoutlet temperature sensor on hotwater pipe.Temperature > 185°F1. Check that the sen

Page 39 - 7.5 Low water flow/pressure

6 720 608 54244Problem solvingNo flame ionization detected withwater flow.1. Verify that all manual gas shut off valves are open.2. Check gas type

Page 40

6 720 608 542Electrical diagram459 Electrical diagramFig. 59 Electrical scheme1 Intlet water temperature sensor2 Outlet water temperature sensor3 Back

Page 41 - 8 Problem solving

6 720 608 54246Sensor resistance charts10 Sensor resistance chartsFig. 60Fig. 61Outlet temperature sensor characteristics3 23 74 24 752576 26 772778 2

Page 42

6 720 608 542Sensor resistance charts47Fig. 62Back Flow characteristics3 23 74 24 75 25 76 26 77 27 78 28 79 29 710 210 711211712 212 713 213 714 214

Page 43

6 720 608 54248GWH 2700 ES Functional scheme11 GWH 2700 ES Functional schemeFig. 63 Functional scheme

Page 44

6 720 608 542Interior components diagram and parts list4912 Interior components diagram and parts list12.1 Interior componentsFig. 64 Components1 Flue

Page 45 - 9 Electrical diagram

6 720 608 542Appliance details52.2 Specifications (Technical data)Approved in US/CanadaCapacityMaximum flow rate: 7.15 GPM (27 l/min) at a 45

Page 46 - 10 Sensor resistance charts

6 720 608 54250Interior components diagram and parts listFig. 65 Appliance overview

Page 47 - Sensor resistance charts

6 720 608 542Interior components diagram and parts list5112.2 Components diagram12.2.1 Group 1Fig. 66 Components Diagram998512367910129141617111315154

Page 48 - Fig. 63 Functional scheme

6 720 608 54252Interior components diagram and parts list12.2.2 Group 2Fig. 67 Components Diagram1324567896720902974.AA JFItem Description Reference1

Page 49 - 12.1 Interior components

6 720 608 542Interior components diagram and parts list5312.2.3 Group 3Fig. 68 Components Diagram151413467821291113161756720902975.AA JFItem Descripti

Page 50 - Fig. 65 Appliance overview

6 720 608 54254Interior components diagram and parts list12.2.4 Group 4Fig. 69 Components Diagram9214134567811111213106720608158-73.1ALItem Descriptio

Page 51 - 12.2 Components diagram

6 720 608 542Interior components diagram and parts list5512.2.5 Group 5Fig. 70 Components DiagramItem Description Reference1 Water valve with engine 8

Page 52 - 6720902974.AA JF

6 720 608 54256Interior components diagram and parts list12.2.6 Group 6Fig. 71 Components Diagram151237695111316141012846720902978.AA JFItem Descripti

Page 53 - 6720902975.AA JF

6 720 608 542Protecting the environment5713 Protecting the environment PackingThe packing box may be fully recycled as confirmed bythe recycling symbo

Page 54

6 720 608 54258Limited Warranty14 Limited WarrantyGeneralAquastar water heaters are warranted by theManufacturer (BOSCH) through BoschThermot

Page 55

6 720 608 542Limited Warranty59

Page 56 - 6720902978.AA JF

6 720 608 5426Appliance details2.3 Unpacking the heaterBefore installing the unit, be certain you have the correct heater for your type of Gas: Propan

Page 57

6720608542© 2009 Bosch Thermotechnology Corp.,Londonderry, NH all rights reservedReplacement Parts available from:Bosch Termotecnologia SAEstrada de C

Page 58 - 14 Limited Warranty

6 720 608 542Appliance details72.4 General rules to follow for safe operationB1. You must follow these instructions when you installyour heater. In th

Page 59 - Limited Warranty

6 720 608 5428Appliance details2.5 Dimensions and Minimum installation clearancesFig. 6 Dimensions1 On/Off button2 Reset button3 Program key4 Power ON

Page 60 - Tel. 866-330-2730

6 720 608 542Installation instructions93 Installation instructions3.1 Tools required for installation• Philips head screwdriver• Flat head screwdriver