Safety instructions
1-7
1070 080 059-101 (2001.04) GB
DANGEROUS ELECTRICAL VOLTAGE
Before the modules are installed, the respective mounting station
must be safely isolated from supply and properly safeguarded to pre-
vent unintentional or unauthorized reclosing.
CAUTION
Short circuits!
When cut-outs are drilled or sawed in switchgear cubicles, metal
burr may get into modules already installed there. Or, when cooling
water lines are connected, water may leak into the modules installed.
The possibility of short circuits occurring in the process or even the
destruction of the devices cannot be entirely ruled out.
Therefore, guard any existing modules well before you install a new
module! Any and all warranty excluded in case of non-compliance.
CAUTION
Heat accumulation!
MF inverters must be mounted with a minimum clearance of 100 mm
on top and at the bottom. Without this minimum clearance, heat may
accumulate and cause inverter failure.
CAUTION
In the case of aircooled MF inverters, the temperature inside the
housing must stay within the specified range. MF inverters must al
ways be operated under forcedair cooling conditions. Convection
cooling will not be sufficient!
CAUTION
Leaks in the cooling water circuit may cause consequential damage!
Cooling water leaks may damage adjacent components. Therefore,
when mounting water-cooled modules, always ensure that other de-
vices in the switchgear cabinet are well protected against leaking
cooling water.