24
Troubleshooting
6 720 617 760 (2008/09)
6Troubleshooting
If the boiler has developed a fault, the display will show, for exam-
ple, EA. E. Here, EA means a boiler fault; the full stop . means an
external fault; E means error (= fault).
If the FR 10 has developed a fault, the display will show, for exam-
ple, 03 E.
Here, 03 refers the the fault number at the FR 10 and E stands for
error (= fault):
B Contact your installer.
If several faults are active, the fault with the highest priority is dis-
played.
Display Cause Remedy (by installer)
01 E Boiler no longer reporting. Check codes and connection of
BUS subscribers.
Incorrect BUS subscriber
connected.
Replace incorrect BUS sub-
scriber.
02 E Internal fault. Replace FR 10.
03 E Temperature sensor in
FR 10 faulty.
Replace FR 10.
11 E New BUS subscriber rec-
ognised.
Check and adjust configuration.
12 E BUS subscriber IPM miss-
ing.
Check codes and connection of
BUS subscribers.
13 E BUS subscriber changed
or replaced.
Check and adjust configuration,
codes and connections.
14 E Inadmissible BUS sub-
scriber connected.
Remove inadmissible BUS sub-
scriber.
AE. E
...
Boiler fault. Correct the fault in accordance
with the details in the boiler doc-
umentation.
Tab. 4