Bosch PMD 7 Specifications Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 157
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
24 | English
2 609 140 996 | (8.5.13) Bosch Power Tools
Maintenance and Cleaning
Wipe away debris or contamination with a dry, soft cloth. Do not use
cleaning agents or solvents.
In order not to affect the measuring function, decals/stickers or name
plates, especially metal ones, may not be attached in the sensor area 6 on
the front or back side of the measuring tool.
After-sales Service and Application Service
Our after-sales service responds to your questions concerning mainte-
nance and repair of your product as well as spare parts. Exploded views
and information on spare parts can also be found under:
www.bosch-pt.com
Bosch’s application service team will gladly answer questions concerning
our products and their accessories.
In all correspondence and spare parts orders, please always include the
10-digit article number given on the type plate of the measuring tool.
Measurement results inaccurate/implausible
Interfering metal
objects in the area of
the sensor
Remove all interfering metal objects (e.g. watch,
bracelet, ring, etc.) from the sensor area. Do not
hold the device close to the sensor.
Auto calibration not
successful
Perform a manual calibration.
Continuous flashing green/yellow/red,
even when no metal or “live” cable is in the vicinity.
Measuring tool is
defective
Send the measuring tool in for service.
* Therefore, please also observe other information sources (e.g. construction plans)
before drilling, sawing or routing into walls, ceilings or floors.
Cause Corrective Measure
OBJ_BUCH-1913-001.book Page 24 Wednesday, May 8, 2013 11:04 AM
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 156 157

Comments to this Manuals

No comments