Bosch D9412GV4 Specifications

Browse online or download Specifications for Fire protection Bosch D9412GV4. Bosch D9412GV4 Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Control Panel

Control PanelD9412GV4/D7412GV4 v2.03 en UL Installation Instructions

Page 2

Figure 2.3: Reset PinCallout - Description1 - Reset pin locked (closed)2 - Reset pin normal (open)10 en | Installation Control Panel2014.04 | 03 | F.0

Page 3 - Table of contents

DiagramsFaceplatesFigure 3.1: FaceplatesCallout - DescriptionCallout - Description1 - Charging status LED (yellow) 8 - Ring2 - Low battery LED (red) 9

Page 4

Power Supply Side Wiring DiagramsD9412GV4/D7412GV4 v2.00 (and higher) Power Supply Side System(D113, D122/D122L, D192G, D928, D1640, D8132) Wiring Dia

Page 5 - Introduction

Notice!For UL Certified accounts, additional power can be obtained using only a UL Listed auxiliary12.0 VDC regulated, power-limited power supply.Noti

Page 6 - Installation

D9412GV4/D7412GV4 v2.00 (and higher) Input Points andPeripheral Devices (D125B, D129, D130) System WiringDiagramSw. Aux PwrZone BZone APnl CommonPnl C

Page 7 - Installing the Control Panel

SDI and Zonex Devices Wiring Diagrams D9412GV4 SDI and Zonex Devices (B420/B426, B450, D1255/D1255RB,D1256RB, D1257RB, D1265, D8125, D8128D, D8129, D

Page 8 - Connecting Earth Ground

Callout ᅳ Description Callout ᅳ Description5 ᅳ Up to 119 D9127U/T POPITs 1The number of D8129 OctoRelays that can be connected to each Zonex terminal

Page 9 - Locking the Reset Pin

6 - Zonex 1: Up to 9 D8128Ds maximum7 - Zonex 1: Up to 8 D8129s maximum11The number of D8129 OctoRelays that can be connected to each Zonex terminal o

Page 10 - 2 - Reset pin normal (open)

D9412GV4/D7412GV4 CapacitiesModule D9412GV4 D7412GV4B208 Octo-input Modules 24 71B308 Octo-output Modules 12 62B420/B426 Conettix EthernetCommunicatio

Page 11 - Diagrams

SDI2 Bus Wiring RecommendationsUse the following SDI2 bus wiring recommendations for SDI2 installation. The SDI2 bus isused by the GV4 Control Panel

Page 13 - D9412GV4

CablecapacitanceOverallcablelength CablecapacitanceOverallcablelength CablecapacitanceOverallcablelength CablecapacitanceOverallcablelengthpF/ft ft

Page 14 - CAUTION:

Keyswitch WiringFigure 3.9: Keyswitch WiringCallout - Description1 - Maintained keyswitch2 - Momentary keyswitch3 - Common4 - Point Input5 – End of Li

Page 15

Power Supply and Power OutputsPower Supply - PrimaryPrimary (AC) Power CircuitThe primary source is a 16.5 VAC, 40 VA, internally-fused transformer (B

Page 16

D8004 Transformer Enclosure Required for Fire SystemsUse the D8004 Transformer Enclosure for the D1640 Transformer in fire and combined fireand burgla

Page 17 - B942W) System Wiring

!Warning!High current arcs are possible. The positive (red) battery lead and Terminal 5 can create highcurrent arcs if shorted to other terminals or t

Page 18

Figure 4.2: Non-PowerLimited WiringCallout ᅳ Description1 ᅳ Conduit required for use with external batteries.2 ᅳ Battery wires3 ᅳ 0.25 in (6.4 mm) min

Page 19 - Figure 3.8: SDI2 Bus Wiring

– Terminal 8: Output C (Switched Auxiliary Power)PTC CB5 protects Terminal 24: Zonex Power.PTC CB1 protects Terminal 32: SDI Power +.PTC CB3 protects

Page 20

F01U265459) contains complete instructions for programming outputs. Refer to Terminals 6and 7, page 27, Fire System Power Formula, page 27, and Termin

Page 21 - Keyswitch Wiring

Terminal 8Terminal 8 provides continuous positive (+) 12.0 VDC Nominal power. Output C interrupts thepower at Terminal 8 when activated. Use Terminal

Page 22 - Power Supply - Primary

SpecificationsVoltage Input(Power Supply)1Primary: Terminals 1 and 2 16.5 VAC 40 VA class 2 plug-intransformer (D1640)Secondary: Terminals 4 and 5 Sea

Page 23 - Power Terminals - Secondary

Table of contents1Introduction 51.1 About documentation 51.2 Bosch Security Systems, Inc. product manufacturing dates 52Installation 62.1 Installation

Page 24 - Figure 4.1: Battery Terminals

SDI Bus B-: 9 VDC 15000 ft (4572 m) maximumSDI2 Bus SDI2 Bus A+; 12 VDC nominal 7500 ft (2286 m) maximum3SDI2 Bus B-: 12 VDC nominal 7500 ft (2286 m)

Page 25

B520 SpecificationsVoltage Input (PowerSupply)Primary: 18 VAC terminal 18.0 VAC, 50 VA class 2 plug-intransformer -TR1850(18.0 VAC, 50 VA class 2 plug

Page 26 - Programming

Recharge Cycle AC ON – Load shed relay resets, battery chargingbegins, Battery Trouble and AC Restoral Reportssent.12.6 VDC – Battery Restoral Report

Page 27 - Fire System Power Formula

TerminalNoTerminalDescriptionRequirements16 POINT 4 Terminal accommodates 14 to 22 AWG, use appropriate wire size based on loopresistance less than 10

Page 28 - Terminal 8

TerminalNoTerminalDescriptionRequirements36 SDI2 POWER Terminal accommodates 14 to 22 AWG, use appropriate wire size based on peripheraldevice current

Page 29 - Specifications

Compatible Accessories1Model Title UL 864 UL985Intrusion cULIntrusionD162 Phone cord D185 Reverse Polarity Module X X X D192G Bell Circuit Sup

Page 30

Compatible Accessories1Model Title UL 864 UL985Intrusion cULIntrusionZX970 PIR/Microwave Motion Sensor with POPIT X RFBT-A3RADION speciality

Page 31 - B520 Specifications

Circuit ClassesOnboard PointsOnboard points, points 1 to 8, are Class B, Style B Initiating-Device Circuits.Zonex Bus or BusesZonex buses are Class B,

Page 34 - Compatibilities

4.6.4 Terminal 8 285Specifications 295.1 B520 Specifications 315.2 Terminal Wiring Requirements 325.3 Compatibilities 345.4 Circuit Classes 374 en | T

Page 35

Bosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.com© Bosch Security Systems, Inc., 2014

Page 36

IntroductionAbout documentationCopyrightThis document is the intellectual property of Bosch Security Systems, Inc. and is protected bycopyright. All r

Page 37 - Circuit Classes

InstallationInstallation PreparationThis section contains a general installation procedure and refers to other sections of thedocument for detailed in

Page 38

Notice!Electromagnetic interference (EMI) can cause problems on long wire runs.Figure 2.1: Enclosure MountingCallout - Description1 - Point chart labe

Page 39

Connecting Earth GroundTerminal 10To help prevent damage from electrostatic charges or other transient electrical surges,connect the system to earth g

Page 40

Figure 2.2: Ground Fault Detect (S4)Callout - Description1 - S4 Locked (Closed). Control panels detects ground faults.2 - S4 Unlocked (Open). Control