1 609 929 W38 | (26.7.10) Bosch Power Tools
Energy Saving Mode
To save energy, you can switch the time indica-
tion in display 39 off.
For this, press and hold the On/Off button 38
when switching off audio operation (see
“Switching Audio Operation On/Off”, page 25),
until there is no indication on the display.
To switch the time indication on again, press the
On/Off button 38 once.
Working Advice
Temperature Monitoring for Battery Operation
When the radio charger is operated only via bat-
tery (no mains supply), the battery temperature
is monitored.
When the battery temperature is below
10 °C or above 50 °C, the temperature
warning k flashes on the display.
When the battery temperature is above
70 °C, the radio charger automatically
switches off to protect the battery. When the
battery has cooled down, the radio charger
can be put into operation again.
Recommendations for Optimal Handling of the
Battery
Protect the battery against moisture and water.
Store the battery only within a temperature
range between 0 °C and 45 °C. As an example,
do not leave the battery in the car in summer.
A battery that is new or has not been used for a
longer period does not develop its full capacity
until after approx. 5 charging/discharging cycles.
A significantly reduced working period after
charging indicates that the battery is used and
must be replaced.
Observe the notes for disposal.
Troubleshooting Causes and
Corrective Measures
Cause Corrective Measure
Radio charger inoperative
No power supply Properly insert mains
plug or battery (com-
pletely)
Radio charger too
warm or too cold
Wait until the radio
charger has reached
operating tempera-
ture
Radio charger inoperative on A/C power
supply
Mains socket faulty Use another socket
Mains plug or cord de-
fective
Check mains plug and
cable and have re-
paired as required
Radio charger inoperative on DC power
supply
Battery contacts con-
taminated
Clean the battery con-
tacts (e.g. by inserting
and removing the bat-
tery several times) or
replace the battery
Battery defective Replace the battery
Battery too warm or
too cold (temperature
warning k flashing or
radio charger switches
off)
Wait until of the bat-
tery has reached oper-
ating temperature
Battery charging or power supply to external
devices inoperative
Mains plug not
plugged-in
Plug mains plug in
(completely)
Battery not inserted
(correctly) for charg-
ing
Have battery engage
properly in charging
compartment