Bosch Conettix C900V2 User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4 | Conettix D6600 Communications Receiver/Gateway
Parts Included
Quantity Component
1 D6600 Communications Receiver/Gateway
1 D6610 CPU Card
1 D6615 CPU Terminator Card
1 D6640 Line Card or D6641 Line Card (Expanded Memory)
1 D6645 Telephone Line Terminator Card
1 D6200CD CD-ROM
Includes the D6200 Programming Software
1 P6601 Battery Cable
1 P6602 Input and Output Cable
Technical Specifications
Electrical
Power Requirements
AC Nominal Operating Range: 120 V or 230 V
AC Maximum Operating Range: 100 VAC to 120 VAC, 220 VAC to 230
VAC, 50 Hz or 60 Hz, 2.5 A maximum
Standby Power: Uninterruptible power supply (UPS)
containing a sealed lead-acid battery,
12 V, 7 Ah to 18 Ah
Current Requirements
One Line Card Installed: Battery: 800 mA
UPS AC Standby: 350 mA
For Each Additional Line Card or Ter-
minal Card Pair:
Battery: 210 mA
UPS AC Standby: 35 mA
One Network Communications Card
Installed:
Battery: 10 mA
UPS AC Standby: 10 mA
Mechanical
Automation Outputs
Automation Outputs: SIA mode
6500 mode
Enclosure
Rack Mount Dimensions (4U): 18 cm x 48.3 cm x 49.5 cm
(7.0 in. x 19.0 in. x 19.5 in.)
Standalone Dimensions: 18 cm x 45 cm x 49.5 cm
(7.0 in. x 17.75 in. x 19.5 in.)
Weight: 8.7 kg (19 lb)
Telephone
Telephone: RJ11C modular jacks, with 26 AWG or
larger wire diameter
Ringer Equivalence Number (REN)
REN: 0.4 B
Industry Canada (IC) REN: 0.2
Display
Screen Dimensions: 1.8 cm x 15.2 cm (0.7 in. x 6.0 in.)
dot matrix LCD, 5 x 7 dots per char-
acter. Shows two separate lines, 40
characters per line.
Indicators: LED display section indicates receiver
status and power.
Inputs and Outputs
For Automation Computer Connec-
tion:
One RS-232 interface port COM3
For External Serial Printer, PC, Mo-
dem, or Network Connection:
One RS-232 interface port COM4
For Parallel Printer Connection: One parallel printer port
Number of Programmable Inputs: Two (wire harness included)
Number of Programmable Outputs: Two (wire harness included)
Optional Input
For Optional Network Communica-
tions Expansion:
One RS-232 interface port COM1
Page view 3
1 2 3 4 5

Comments to this Manuals

No comments